Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by saraycad

  1. saraycad

    Leaking test vacuum pump and devices location

    Honorable, Got request to do design for leak detection system for above ground storage tanks with vacuum pump. Idea is to do double floor and use vacuum pump package (system). Seeking help to define where to locate all package - outside of dike is my opinion (?) but don't know what standard to...
  2. saraycad

    Conversion fuel tank to bitumen tank

    Dear LittleInch thank you for great post. It really gave me a picture of the problems. So much you told me without any hesitating. Thank you so much - you are real teacher. Dear Mr. Dhurjati Sen - as for VOC I put a question of incineration and inertisation to Client. Thank you Best regards
  3. saraycad

    Conversion fuel tank to bitumen tank

    Dear Mr. JStephen, IFRs - so far I know that existing tanks are used for heavy fuel oil (don't have specification at the moment). Also - intention is to use tank as dual - for heavy fuel oil or bitumen - depending of needs of market. My idea is to have additional piping connected to existing one...
  4. saraycad

    Conversion fuel tank to bitumen tank

    Dear all, need advice about conversion - reconstruction - additional equipment - piping - pumping etc. from fuel oil storage tank to bitumen storage tank. Appreciate any guidelines and advice. Best regards
  5. saraycad

    Welding of stainless steel pipes

    Thank you guys, appreciate your effort. Got a main picture - it is stated in Contract - must be 100%. Thnx. Best regards
  6. saraycad

    Welding of stainless steel pipes

    Hi All Have a question and sorry if it is irritant - is it mandatory to do 100% radiography test of welds for stainless steel pipes (e.g. joint of two pipes or pipe and flange), and why? Thank you
  7. saraycad

    Hello everybody, is it possible to

    Thank you mk3223 and pmover
  8. saraycad

    Hello everybody, is it possible to

    Hello everybody, is it possible to get a list of documentation to be delivered within TEG unit delivery? Thanks in advance for any clue. Best regards
  9. saraycad

    For vertical fuel gas knock out dru

    For vertical fuel gas knock out drum need clue or template for installation, operation and maintenace. Thank you
  10. saraycad

    Piping Class C12A

    Thank you all. Got what I asked for. Appreciate. Best regards
  11. saraycad

    Piping Class C12A

    For certain project we don't have piping classes, but got a temperature, pressure and fluid properties. How can we built class in order to have all piping components (fittings, valves etc.) to satisfy certain class eg. C12A. Is there standard (nomenclature for piping classes) Thank you
  12. saraycad

    I want make a standard

    Try http://www.turvill.com/t2/free_stuff/index.htm If not, George Omura is my favorite AutoCAD 2000 book. Actualy, almost every serious book about AC will give you explanation about question you put! Regards!
  13. saraycad

    Protecting AutoCAD Files ?

    What do you (and others) think about converting dwg to pdf files? Is that secure enough? Regards!
  14. saraycad

    Upgrading from Autocad 2000 to autocad 2002??

    From my point of view, there is some additional issues which brings up AC2002 to the top. One of them is spatial dimensioning which I found great. Other one is so called PointA which brings you the best tips about AC (after this site, of course). There is Associative Dimensioning (you already...
  15. saraycad

    Draw Rectangle

    It works in 2002. Maybe you need reinstallation. Try with typing into command line as follows: Command: rec and Enter. If you dont get wright prompt, you need to install AC again! Good luck!

Part and Inventory Search