  1. lisica

    Concrete tutorial

    There are good watch and learn videos on their site. http://www.csiberkeley.com/Support_WL_SAP.html
  2. lisica

    How to define a concrete T-section ?

    Hello Why do you need T-section as concrete column? I think sap2000 can't design concrete column defined as T-section. Check what types concrete design supports.
  3. lisica

    Geometry of the structure

    I am not sure what you are looking for, or why you need that. But if you are new to ETABS there is good Watch and Learn tutorials on their site. http://www.csiberkeley.com/Support_WL_ETABS.html
  4. lisica

    Bending moment sign convention

    In my country and in most of Europe, the bending moment is plot on tension side. That's convention and we are using it. Neither of us can't change that. So, depending on country where you work, use one or another convention.
  5. lisica

    How to define a concrete T-section ?

    Hi, choose the T-shape from steel section, and then pick concrete material instead of steel from drop down box when modifying the properties.
  6. lisica

    Bending moment sign convention

    Well we are learnt to be more engineers than matematicians. If a students can understand the nature of problems there are not problems with reversing the signs of coordinate system.
  7. lisica

    Bending moment sign convention

    Of course its not fixed. But the moment side is not fixed also. On the cantilever beam we put rebar on the top side and moment diagram we plot also on the top side.
  8. lisica

    Bending moment sign convention

    I plot the moment digram on tension side. Why the moment diagram is shown on tension side? We cover the tension with rebar, so I think that's the reason for showing the moment on the tension side.
  9. lisica

    Structural Abuse

    Just like it writes: "Never over estimate people inteligence - some people are stupid"
  10. lisica

    property modifier in section properties

    It is clear why the torsion is developing. Try to put zero in the properties. Analysis will be completed without problems if it's compatibility torsion.
  11. lisica

    property modifier in section properties

    There is the equilibrium and compatibility torsion. So I think, if the torsion is not needed for equilibrium there should not be any problems if you put 0 instead of 1.
  12. lisica

    How to calculate drift of response spectra analysis?

    OK, I agree with you. My code requires using Ex+0.3Ey or Ey+0.3Ex, so I am using this relation. Thank you for your post!
  13. lisica

    How to calculate drift of response spectra analysis?

    However, it depends on your local code. Eurocode 8 demands taking 30% of influence from ortogonal direction. So, it would be X+0,3Y or Y+0,3X.
  14. lisica

    How to calculate drift of response spectra analysis?

    Hi... The earthquake waves are comming from one direction. You don't need to sum the influences from two ortognal directions. Just analyse the influnce in two main directions (X i Y in most cases) separately.
  15. lisica

    question on assing "area load"

    Hi, can you tell as an example where I can see the difference between that assigns? When should we use the first one and when the second one? thx