Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. cleagl

    Pier near a foundation wall

    Hello Fellow Eng-Tips folks, I have a footing I need to put right next to an existing basement wall. I have read the few posts there are, but alas none are really similar to this condition. This is a small house bump out (about 6ft x 25ft) along the entire side of the house. Bump out is one...
  2. cleagl

    IRC and Wood Diaphragms

    Hi Fellow EngTips people, I am now doing residential homes, and need some opinions. No where (that I can find) does the IRC 2015 mention wood diaphragms. Nothing in Floors (Chap 5) and nothing in Roof-Ceiling (Chap 8). There is a reference in Section 804, but that is for cold-formed framing...
  3. cleagl

    Enclosure Transfer Rate

    Thanks for the replies. The vent is uni-directional and can pass 1.3 mL/min. The enclosure will be rated for IP 69k Ingress protection (The standard says something like 70 deg C water at 1400 psi, at 6” away for 3 mins, no leaks). The end user will clean the enclosure from the outside with...
  4. cleagl

    Enclosure Transfer Rate

    Hi Fellow EngTips people. OK so here’s the problem. I am working on a thermal transfer problem. I am a mechanical engineer that hasn’t done thermal in a while, but here’s where I’m at….. A 304 Stainless enclosure approximately 350mm W x 200 D x 900 H. The steel thickness id 1.5 mm. I need...
  5. cleagl

    LTB of a Vierendeel Truss

    Some information.... dhengr made some good suggestions regarding modifying the geometry/physical form to aid in the way the truss handles the moment. However,... The geometry is fixed for several reasons. 1. This is a part of a standard product line. The form and layout are standardized for...
  6. cleagl

    LTB of a Vierendeel Truss

    So here is a drawing of the truss I am working on right now. 54'-0" long x 1'-0" high. Suspended by (4), 1/4" dia 7x19 cable. The ends cantilever 7.5' past the last support points. There really is no lateral bracing at all. Top and bottom chords 1.5" sched 40 (or sched 80) pipe. verticals...
  7. cleagl

    LTB of a Vierendeel Truss

    Thanks very much for all the helpful comments. I have modeled this in RISA, but don't have a good feel for the magnitude of the explicit imperfections. When I have done buckling analysis on shells, I did a separate analysis just to determine the magnitude of the imperfection. Here I can only...
  8. cleagl

    LTB of a Vierendeel Truss

    Greeting fellow eng'ers I have a engineering problem that comes up time and time again in our industry, but as far as I know, very few people have proposed a reasonable solution. I need to be able to calculate when a vierendeel truss will buckle out-of-plane. Context: We manufacture 2-D...