  1. solidspaces

    RETURN BENDS FOR SPRINKLERS

    Return Bends on pendant type wet sprinklers when the network is supplied by raw water sources. Return bends are also not necessary on wet systems that use a potable water supply. There is insistence about their use for the reason that, black steel pipes would eventually corrode on the inside and...
  2. solidspaces

    Duct Sizing by Equal Friction Method using Varitrane Software

    The ducting from our Air Handling units goes all the way to the VAVs and from there to the diffusers. Each VAV serves about 4 diffusers in the rooms. We are using Trane Company’s VARITRANE equal friction duct sizing software for the design. There are a couple of difficulties being encountered...
  3. solidspaces

    Hydraulically Calculated Pipe Diameters for Fire Fighting Networks

    I am searching for the software to calculate hydraulically the pipe diameters of the firefighting network for extra hazard classification of the sprinkler system as per NFPA. The sizing is to be calculated hydraulically and not by the Pipe Schedule System of NFPA. In Chapter 13 of NFPA there is...
  4. solidspaces

    Application of Pascal's Law in a tall vertical pressurized pipe with water as in Fire Standpipe

    According to Pascal’s Law, the pressure inside a chamber that is full and pressurized with a fluid is constant. Does this imply that the static pressure at the base of the pressurized chamber like a very tall column of pipe (in the vertical position) is the same as the static pressure measured...
  5. solidspaces

    Diesel Fire Pump Fuel Tank Fill system

    We have a fire pump set consisting of one electrical pump and a jockey plus the Diesel Pump that has a 1 meter cube capacity fuel tank adjacent to it. There is no automatic fill option in the fuel tank. Are we in violation of NFPA if the fuel tank has no automatic make up system, no sight glass...
  6. solidspaces

    Non Ducted Return Air to Air Handling Units

    Achieving the Desired Return Air quantities from occupied spaces. The HVAC System consists of roof mounted Air Handling units for a single storey building that has many rooms. The system is designed for 20% fresh air and 80% return air that is achieved in the mixing box of the air handler. The...
  7. solidspaces

    underground Pump Room safety of electrical safety due to flooding

    the underground Pump Room of our decorative fountains does not have an automatic submersible pump to de-water the underground pump room in the event of leakages from piping or adjacent water tank. Since there is electrical power and control panel in this underground installation, it could pose...
  8. solidspaces

    pump and system curves

    the performance of our chilled water pumps is attached. • There are four pumps on duty (the pump selection and duty point performance is on page 1 of the attachment). • We obtained readings of each pump with all the four pumps running. (Curve is on page 2 of the attachment). • We also took the...
  9. solidspaces

    Temperature reduction in shaded versus unshaded area under the Sun

    The Steam for humidification of supply air is injected in the supply Air Duct by a standalone humidifier at the Roof that is open to the Sun. The maximum ambient temperature for the electronic controls of this humidifier as specified by the manufacturer is 40C. The ambient temperature at the...