Hi All,
We are in process of producing a heat treated flat bar made from Cast Iron(FG260).
This cast iron bar is used for supporting the conveyor belt in an Industrial oven.
The cast iron bar is machined as per the drawing & heat treated by Induction hardening to 1.5 mm case depth...
Hi Everyone,
We are Industrial oven manufacturers & we generally use Gas burner system with fuel gas trains having Main & Pilot gas lines.
We have some important questions regarding Pilot Gas train., see details below.
1. When do we need Pilot Gas Valve Assembly ?
2. Does...
Hi All,
I am looking to find an alternate source for Fixed Range Positioner Cylinders( Variable Stroke Pneumatic Cylinder ) See below link for more info.
http://store.norgren.com/uk/en/detail/m_1525_75/fixed-range-positioner-cylinders
We are using this Variable Stroke Pneumatic...
Hi All,
We are using Ribbon Pipe Burners for baking Tunnel oven, The Burners lit with blue flame in the morning without any problems, but after sometime the Flame turns to yellow.
The ambient( Oven Room temperature) is around 65 deg C (during Oven operation)
The combustion air for the...
Hi All,
I am trying to figure out the problem on our Tunnel oven supplied three years ago to our customer.
Recently, we found that the Water is coming of the Tunnel Oven through Gaps of Each Modules.
I am being asked to verify/check the Exhaust fan CFM rating of existing fans. whether...
Hi All,
I am interested to calculate/Estimate Heat Transfer Coefficient(h) using Solidworks Flow Simulation Software.
I have posted in Solidworks Flow Simulation Software forum also. see following link.
http://www.eng-tips.com/viewthread.cfm?qid=330053
Pl. let me know your views on...
Hi All,
I have done Analytical Excel spreadsheet calculation for Estimating Heat transfer Coefficient(h) for array of Nozzle Jets (Nozzle Plate) with certain distance from Impingement surface(Oven Belt) for a forced convection air Impingement Oven.
I am interested to know whether Solidworks...
Can anyone help in finding correct nusselt number correlation for following condition?
Multiple array of air jets (nozzles) in Forced convection air impingement ovens
I am trying to figure out maximum heat transfer coefficient (h) based on nozzle diameter (D) and distance between nozzle...
Hi,
I need to calculate Minimum number of threads required for two pipes to engage, The Pipes are having NPSM (American Standard Straight Mechanical Pipe Thread)
Pipe size = 4"-8TPI (NPSM Thread)
The pressure in the pipe is around 75 PSI.
I have considered two threads for engagement, Is...
Hi,
I need to calculate Minimum number of threads required for two pipes to engage, The Pipes are having NPSM (American Standard Straight Mechanical Pipe Thread)
Pipe size = 4"-8TPI (NPSM Thread)
The pressure in the pipe is around 75 PSI.
I have considered two threads for engagement, Is...
Hi All,
I am looking for High Temperature Linear Actuator for Conveyor Oven Belt Tracking system.
The linear Actuator should withstand a temperature of 250-300 deg Centigrade or 480 deg F to 575 deg F
Can anyone help me to find suitable linear Actuator manufacturer for High Temperature...
Hi All,
I am looking for High Temperature Linear Actuator for Conveyor Oven Belt Tracking system.
The linear Actuator should withstand a temperature of 250-300 deg Centigrade or 480 deg F to 575 deg F
Can anyone help me to find suitable linear Actuator manufacturer for High Temperature...
Hi,
Does anyone has used bearings inside a Industrial
oven.(Inside baking chamber)
We tried to use high temperature bearings in an oven but bearing seized after 3-4 weeks of operation.
Can anyone shed more light on this........
Hi,
Can anyone help in calculating Total Heat required (Btu/hr)from basics(Fundamentals) for Baking a product(biscuit)in an oven.
I have considered the following procedure.
1. Heat required to raise the temperature of dough to 100 deg C (212 deg F)