  1. TransD

    Proportional Valve

    I have a 0 to plus or minus 10 volt proportional valve that is controlling a cylinder. It is a parker D31fh type. The hydraulic pressure ranges from 1600 to 1850. The pump will start at 1600 and shut off at 1850. My problem is with the new proportional valve it cycles the pump every 4 minutes...
  2. TransD

    wiring equipment

    I have a lathe and a drill press I need to wire up. They are mounted to a concrete floor. In order to get the conduit to the equipment I will need to either cut a path in the concrete or use a flexible cord, plug, and receptacle. I cannot find where the cord option is legal according to code. I...
  3. TransD

    Blown transformer Primary fuse from Secondary overload

    Hi, At work I noticed a phase loss from one of our transformers. After making some checks I noticed one of the three transformer primary fuses was blown. I am trying to figure out if it was due to a secondary overload, how much current it would take to blow the primary fuse, and why didn't...
  4. TransD

    generator rotor brakes

    Hello, I work at a hydroelectric plant that uses the field of the rotor for a brake once the unit is taken offline. As you can imagine if there is a little wicket gate leakage, it can take a long time to stop. We have had issues with the exciter tripping due to raising the voltage too...
  5. TransD

    static exciters, voltage regulators

    Does anyone know of a good book or manual on static exciters and voltage regulators in general? Something to use for foundational information or teaching for most exciter configurations. Thanks for any help.
  6. TransD

    Directsoft 5 Subroutine

    I am programming a subroutine in Directsoft 5. The subroutine scrolls through indicator lights when activated. When coming out of the subroutine, sometimes one of my indicator lights sticks on. It depends on when I flip the switch to come out of the subroutine as to which one of the lights stick...
  7. TransD

    Generator Noise

    I work at a hydroelectric plant with 6 horizontal units. Recently 2 units were rewound. The voltage rating of the stator was changed from 4000 volts to 4800 volts. There are 44 field poles on each unit which were also rewound. After they were rewound,the generators were considerably louder than...
  8. TransD

    Collector Ring Vibration

    To measure vibration on the collector rings of my generators, I am using an insulated rod touching the top of my brush rigging. The vibration monitor is the CSI 2130. My question is how man mils is normal and at what point (mils) is there too much vibration? My generator is turning at 164 rpms...
  9. TransD

    Collector Rings

    My boss wants me to find the equipment and learn how to true the collector rings on our generators. They are about 3 to 4 feet around. Does anyone have any ideas on where to get the equipment and instruction? Two things I was thinking about was what is the grit of the rock used for cutting and...
  10. TransD

    I/O Fault table

    I have heard that service request 15 will allow me to log the last PLC I/O fault into a register. I am using Proficy 6.0 Does anyone have any suggestions for implementing service request 15? Thanks.
  11. TransD

    Station Battery Load Testing

    Hello, It is time for our five year battery test at our powerhouse. It is a 134vdc system. We will be paralleling 12 volt batteries with our 2.2 volt batteries during testing. Other than verifying the polarity, are there other concerns I should look into? Thanks.