Search results for query: *

  1. SidiropoulosM

    Busbar is Tip-Master at eng-tips

    Busbar, Congratulations and keep up the good work. Your helpful and illuminating posts are a source of learning for many of us.
  2. SidiropoulosM

    Transformer Noise

    Any ideas on reducing noise from a 230/115 kv transformer without reducing operating voltage? The noise occurs when the transformer operates at 107% nominal voltage.
  3. SidiropoulosM

    Motor Undervoltage Protection

    In a transient stability study I noticed that induction motors are modeled with undervoltage protection. The model shows a voltage pick-up setting of 0.60 pu and a time delay of 30 cycles. Do these values seem right? What is the range of typical settings? Any info would be greatly appreciated...
  4. SidiropoulosM

    Transformer Explosion

    There was an explosion of a 500/230 kv transformer in southern California last Friday. The explosion escalated to a fire through the entire substation. Sabotage is not suspected. All transformer experts out there, I would like to know what are the various causes of catastrophic transformer...
  5. SidiropoulosM

    I have a 75-year old 115/69 kv tran

    I have a 75-year old 115/69 kv transformer, which serves a load area in Northern California. My studies show that I can improve the voltage profile on the 69 kv network by changing the fixed no-load tap on the 115 kv side. This would be much cheaper than installing capacitors on the 69 kv...
  6. SidiropoulosM

    Power quality issues

    There is a concern among many electric power professionals that deregulation and competition in the industry may have negative effects on power quality and reliability. I would like to invite comments on power quality, with a focus on the following issues: -What do you understand by the term...
  7. SidiropoulosM

    The thermal capability of a transmi

    The thermal capability of a transmission line depends on the physical characteristics of the conductor and on a complex combination of environmental parameters. Electric utilities have generally applied static (or "fixed") ratings, based on a set of conservative assumptions. Dynamic...
  8. SidiropoulosM

    Power substation relay misoperations

    Any information on misoperation of power substation protection systems would be appreciated (categories and causes of misoperations, outage statistics etc.) Michael Sidiropoulos Transmission Planning - Pacificorp
  9. SidiropoulosM

    Transmission Line Dynamic Thermal Ratings

    The thermal capability of a transmission line depends on the physical characteristics of the conductor and on a complex combination of environmental parameters. Electric utilities have generally applied static (or "fixed") ratings, based on a set of conservative assumptions. Dynamic...