  1. thejonster

    Wood roof purlins with roll blocking on steep glulam trusses: is friction component allowed to resist sliding?

    With wood purlins, I'm discovering that I have to resist rolling, this due to the lateral component of the purlin reaction on a sloped roof and the distance from the centroid of the purlin to the bearing point. This is significant because the reaction force, normally taken in bearing is large...
  2. thejonster

    Would use of a corner bar in standard hook shorten the development length?

    I'd love to reduce the dev length for my retaining wall bars in the footing making a more efficient use of concrete using a longit bar in the corner of my standard hook. This would be analogous to a stirrup hook, which works in beam shear with small dimensions, right? A force is a force. It's...
  3. thejonster

    Any circumstance where you'd design without a geotech report?

    I have an owner who seems to think that helical piers just need to come to torque and voila no geotech report needed. This is an area I've spent too much time thinking about, despite previous replies seen to this same question (see bot of post), I'd like to know what y'all think with the info...
  4. thejonster

    Fees vs liability for design to be manufactured

    a mechanical engineer friend who runs his own business said that he was told to assume no liability for a design that will be manufactured, they're not hiring you for your insurance coverage, they're hiring you for your expertise. How do you mech guys handle liability in design for a part that...
  5. thejonster

    Reuse of design in manufacturing - fees vs liability

    In regard to reuse of design, this is a twist I haven't seen on Eng-tips. I wanted to discuss fees vs liability in manufacturing. I have a question in to my lawyer regarding this and wanted to know what other managers / business owners thought. I'm being asked to design shear walls for...
  6. thejonster

    With bracing for steel beam in uplift, is bracing ignored as purlin support for gravity?

    I need bracing for my steel beam in uplift and this is bugging me. I've noticed in PEMB that huge tapered built up plate girders with tiny angles braces to purlins don't seem change the size purlin it's attached to, and the tiny angle doesn't seem like it could carry a big kicker load. In this...
  7. thejonster

    Expert witness work: fee multiplier? First time, risks involved?

    There are only a couple applicable topics on a search of 'expert witness fee', with some great clues but nothing conclusive for me. My old firm / I was brought in late to a large project that had a lot of problems years ago to solve several issues structurally. It's now going to arbitration...
  8. thejonster

    Are commercial electronic structural detail libraries worth it? Examples?

    I want to purchase an Electronic Structural Detail Library and have come across a few McGraw-Hill Electronic Structural Detail Library Axiom Solutions, LLC-Handbook of Structural Details For Buildings First Edition - 500 Pages Paperback Handbook Civilworx-Libraries The McGraw-Hill library is...
  9. thejonster

    Appropriate to base stamp/letter off of information provided by others?

    A new client missed an inspection and needs an engineering stamp so they don't have to tear a deck down / rebuild etc. This city official/inspector wants a letter from an engineer stating at a minimum that I am OK with how it's constructed because it's not the normal way that decks are built...
  10. thejonster

    Structural Software comparison spreadsheet, input welcome

    I'm starting my own firm, I'm familiar in my career with RAM and RISA mostly and wanted to see what else was out there. I created a spreadsheet for my use to compare suites and wanted to share with anyone looking into this as well. I've favored the perpetual stand alone licenses, but have...
  11. thejonster

    Knee brace issues, unreasonable deflections & drift, **solved**, fixity problem / bug

    I'm designing an independent steel mezzanine level (apx 30x50’ x 15 ft tall) inside of another building. I am having trouble getting reasonable results for loading in the knee brace direction (load acting in direction of strong axis beams and braces pinned m22 minor & m33 major, weak axis...
  12. thejonster

    ETABS removed connection design and detailing capabilities

    I have downloaded the trial version of ETABS and I've been using it for the last few weeks. I was excited to find a software that is not subscription-based and that did so much. I'm starting my own firm and like the idea of having software I own rather than rent. I was particularly excited to...
  13. thejonster

    Are column strip middle strip assumptions required to model 2 way slabs that are post tensioned?

    Column strip middle strip assumptions concentrate moments & shears in ultimate, and stresses in service for mild 2 way slab design.. should this also apply in prestressed/ Post-tensioned design? I was very interested in ACI 318-14 researching this question because the re-organization put mild...
  14. thejonster

    Weathered oversized wood beam

    My question is buried below: does anyone know if the code says anything about weathering in regard to the Cm factor? A beam that was oversized, 6x14 x 14' (butts to a 6x4 x 24') used on one end of a 38' long open patio built in the 80's has a weathered/grey end (45 deg from the open end), but...
  15. thejonster

    Can footing surcharge increase passive pressure on key?

    I designed a restrained masonry retaining wall and I am taking another look at my wall and I'm taking another look at it. I pinned the wall base at the top of my footing for the DD/bid, and that looks like a bad idea to me now. I'm thinking I should run the same pressures on down into the 2'6"...
  16. thejonster

    Seismic R-value of old stucco/plaster walls

    This is a 3 part question.. Background: I'm designing a patio enclosure with many windows and narrow shearwalls using FTAO for a restaurant addition/expansion. This is adding on to an old stucco/plaster wood frame building, an old gas station built as late as the 40's. The patio, extending...
  17. thejonster

    Free Download of Building Codes

    Is this legal? (I don't know!) City of Los Angeles Building Code 2008 http://www.archive.org/details/gov.ca.la.building.code.vol1 http://www.archive.org/details/gov.ca.la.building.code.vol2 California Building Code http://public.resource.org/bsc.ca.gov/index.html Public.resource.org says...
  18. thejonster

    Aluminum Beam - Minimum web stiffener depth, local buckling

    We don't normally do aluminum, but we're trying to help out a client that is in a bind without sticking our neck out in the process. My question is: does the ADM or AISC SCM specify the required depth of a stiffener at intermediate locations of an element (10" leg on a L-shape) with a free edge...