Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: Brandon
  • Content: Threads
  • Order by date
  1. Brandon

    AASHTO 8th Edition - Equation 5.6.4.6-1 (spirals)

    In AASHTO 8th Edition, Equation 5.6.4.6-1: rho=(4Asp)/(dc*s) >/= 0.45(Ag/Ac-1)(f'c/fyh) does anyone know for certain if the term "Asp" is meant to be just the area of a single bar of the size being used for the spiral, or is it twice that (i.e. "2 legs" as for shear reinforcing)? I have a 42"...
  2. Brandon

    Spalling of concrete slab soffit - residential garage "roof"

    A friend's house has a garage with a concrete slab "roof" that is the floor of the living space above. House built probably in the 1920s. Most of the concrete cover has spalled off the slab soffit in lines following the rebar (orthogonal grid)and the rebar is obviously corroded. I haven't been...
  3. Brandon

    AASHTO LRFD Strut & Tie Provisions

    Does anyone know if the recommended changes contained in this report have been adopted in the latest (7th) edition of the AASHTO LRFD Code?
  4. Brandon

    AASHTO LRFD Prestressed Concrete Allowable Tensile Stresses

    Question about the following provision of the AASHTO LRFD Bridge Design Specifications: Section 5.9.4.2.2 - Tension Stresses Table 5.9.4.2.2.-1 - Tensile Stress Limits in Prestressed Concrete at Service Limit State after Losses, Fully Prestressed Components Other Than Segmentally Constructed...
  5. Brandon

    AASHTO Prestressed Concrete Allowable Tensile Stress (5.9.4.2.2.)

    Question about the following provision of the AASHTO LRFD Bridge Design Specifications: Section 5.9.4.2.2 - Tension Stresses Table 5.9.4.2.2.-1 - Tensile Stress Limits in Prestressed Concrete at Service Limit State after Losses, Fully Prestressed Components Other Than Segmentally Constructed...
  6. Brandon

    Spread footing sliding resistance

    Section 10.6.3.4 of the AASHTO LRFD Bridge Design Specifications gives provisions for calculating sliding resistance of spread footings. For footings on clay, the specifications state that the sliding resistance shall equal the cohesion of the clay. This is my first use of this particular...
  7. Brandon

    AASHTO LRFD - wall sliding provisions

    Section 10.6.3.4 of the AASHTO LRFD Bridge Design Specifications gives provisions for calculating sliding resistance of spread footings. For footings on clay, the specifications state that the sliding resistance shall equal the cohesion of the clay. This is my first use of this particular...
  8. Brandon

    AASHTO LRFD Retaining Wall Sliding Provisions in 10.6.3.4

    Section 10.6.3.4 of the AASHTO LRFD Bridge Design Specifications gives provisions for calculating sliding resistance of spread footings. For footings on clay, the specifications state that the sliding resistance shall equal the cohesion of the clay. This is my first use of this particular...
  9. Brandon

    Shear stud diameter in composite bridge beam

    Designing a steel beam vehicular bridge with a composite concrete deck. Initial run resulted in a W21x68 as the optimal section. However, shear stud design would require rows of (3) 7/8" diameter studs spaced transversely across the beam flange in some locations. The problem is that the flange...
  10. Brandon

    Soldier piles using encased steel railroad rail

    I posed this question over in the Structural Engineering forum, but it occurred to me that perhaps the retaining wall guys might have had some first hand experience with this. In short we have a contractor proposing to utilize salvaged steel railroad rail as reinforcement for drilled concrete...
  11. Brandon

    Concrete Encased Steel Beam

    I have been tasked with the review of a soldier pile type wall design wherein the design-build contractor is proposing to use steel railroad rails placed into a drilled hole and filled with structural concrete. I am trying to determine if this can be treated as a composite beam based on the...
  12. Brandon

    Background of Strut and Tie Method

    What are the reasons for using a strut and tie model for deep beams? Will traditional design methods for flexure (Whitney stress block) and shear yield unconservative results for deep beams? Or does the strut and tie model just produce more economical designs? I have never used strut and tie...
  13. Brandon

    Sheet Pile Retaining Wall to Resist Guardrail Impact Load

    We are designing a steel sheet pile retaining wall that will be used as temporary shoring for construction of a bridge foundation, during which it will retain about a 6 ft. depth of cut. It will be left in place after construction is complete and will then serve as a permanent retaining wall to...
  14. Brandon

    Lateral pressure from narrow granular zone between two walls

    Does anyone know what the lateral earth pressure would be for the case of a narrow (~2 feet) zone of granular backfill placed between two parallel walls? The specific case is the basement wall of a condo we were asked to investigate. The masonry block basement wall is buckling inward and we are...
  15. Brandon

    Soil Nailing and utility excavation

    Does anyone have any experience with /recommendations for excavating for utility trenches in the vicintiy of soil nails? Within what distance from the nails should excavation be resticted or prohibited?

Part and Inventory Search