  1. M40A

    Pre-packaged, Nonshrink Grout Testing (Field)

    We are supporting a project demanding strict quality. The client is proposing to use Non-shrink grout under base-plates and other structural components. We can not find an ASTM Standard that specifically addresses "Field" testing of the grout. We have referenced the following ASTMs: C 109 C...
  2. M40A

    Pre-packaged, Nonshrink Grout Testing

    We are supporting a project demanding strict quality. The client is proposing to use Non-shrink grout under base-plates and other structural components. We can not find an ASTM Standard that specifically addresses "Field" testing of the grout. We have referenced the following ASTMs: C 109 C...
  3. M40A

    Anchor Pull-Testing

    We are testing post-installed anchors in concrete, utilizing a hollow-cylinder jack, pump and pressure gauge type assembly; similar to the configuration referenced in ASTM C 900 and/or ASTM D 4435. We have calibrated the pressure gauge and standardized the system in accordance with Annex A1...
  4. M40A

    Welded Connection / Rebar

    A detail calls out for rebar to be welded; yet, welding rebar under harsh scrutiny for this project may not be a viable option? The location of the welded connection forms a "cross" and was wondering if there are any mechanical connectors made for that type of application?
  5. M40A

    Soil Subgrade Modulus

    We are trying to determine the modulus of a soil subgrade underneath a concrete slab in an existing structure. We are cutting a 3' x 3' square hole in the slab to access subgrade. What would be the most cost-effective way to determine this?
  6. M40A

    Water / Cement Ratio

    Doesn't the absorbed water, in aggregate(s), effect the water/cement ratio? The below definition would indicate not, but couldn't the absorbed water play a part in the total water/cement ratio? As defined in ACI 2008: Water-cement ratio - the ratio of the mass of water, exclusive only of...
  7. M40A

    Max. Size Aggregate in Grout Mix

    We have a requirement that the max. size aggregate in a grout mix be 3/8" and be batched from a ready-mix plant. What may be some benefits of have a 3/8" aggregate in a mix?
  8. M40A

    Concrete Cracking

    There was a new building constructed (less than 2 months old) and the reinforced concrete slab has considerable surface cracking near the control joints in some instances and nearly in the middle of others. There are no records of control testing during the construction of this bldg -...