Hi Folks
as what is an IBC storage area cover with an overhead roof (but not on the side walls) classified outdoor or indoor
I am considering a sprinkler system in accordance with NFPA 400 and NFPA 13
for fire sprinkler protection at appear no other choice than deluge sprinkler over entire...
Good day folks
who can direct me to applicable source or guideline...
I need to select pressure safety relief valve for high temperature hot water system (not steam) operating 188 °F (87°C )
The vessel volume is 1,300 gallon ( 5,000 liter )
The hot water source is a boiler high temperature...
Hi Folks
what NFPA code provide guidance on requirement for suplementary hydrant and hose stream flows to be allowed for fuel depot facility
The facility has mounded fuel storage with loading and decanting bay (for which foam/ water sprinkler protection will be provided for )
requiring guidance...
hi Folks
repost from nuclear engineering forum
do anyone has any reference regarding the settling velocity of yellow cake (uranium oxide) dust.
Need it to ensure min velocity is adhered to prevent settling in duct system
thanks
hi Folks
do anyone has any reference regarding the settling velocity of yellow cake (uranium oxide) dust.
Need it to ensure min velocity is adhered to prevent settling in duct system
thanks
hi folks
i am missing something
i am required so size immersed copper U-tube HX in a tank
known
required heat capacity (kw)
Hot side
Th in : 120 °C
Th out : ?
Cold side
Tc in vessel : 20°
Tc out : ?
Vessel target temperature : 80°C
LMTD method not applicable since not all temperatures...
Hi folks
is it viable to provide an economizer heat exchanger for preheating on the stack outlet of high temperature hot water boiler ( fire tube) - LFO fired?
is their any pitfalls to be aware of using an economizer on an LFO fire tube boiler?
many thanks
Hi Folks
what is the generally accepted emission removal process for Offgas mainly containing SO2 and SO3
Any reference or literature you could recommend?
many thks
Hi Folks
i am looking for literature on the sizing narrative to select electrical actuator for dampers on industrial ventilation ( torque etc)
are you aware of any reference ?
good day folks,
I am exploring options for screening option for submersible type effluent pump station
daily flow 1500 m³/day
we have relative deep invert level on in -feed pipe
options
-manual incline bar screen [ not deemed feasible due to depth of in-feed]
-mechanical rake screen [...
good day folks,
I am exploring options for screening option for submersible type effluent pump station
daily flow 1500 m³/day
we have relative deep invert level on in -feed pipe
options
-manual incline bar screen [ not deemed feasible due to depth of in-feed]
-mechanical rake screen [...
Hi all,
on a PRV station on water distribution..
to my knowledge it is good practice to provide Pressure regulating valves PRV) in two paralel lines to cater for for flow fluctuations
big line to cater for high flow and small line to cater for low flow situations
selection of large line not a...
With the current pandemic going on
what is the anticipated upgrade expected of guidelines
especially on recirculating air conditioning systems
what would be the best technology to fit on the return air side of FCU's etc
HEPA filtration will result in huge pressure losses
whast your take?
hi everyone
I am looking for references on hydraulic calculations ( pipe, pump sizing etc) for hydrocarbons
which formulas are applicable etc.
any advice would be appreciated.
Hi There
what is the methods applicable to establish cooling load required for equipment in data center
area based ( w / m2) or breaking it down per equipment intended
what type of data center equipment is most sensitive to humidity regulation
thank you
hi There
we have a scenario to expand the current compressed air delivery ( flow)
what is the practical implications of running 2 rotary screw compressors in parallel?
Hi Every one
how deep could one go with invert level of inflow from practical perspective?
intended grit removal is by portable jet pump.
is depth of 3 meter sensible?