Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: Corgas
  • Content: Threads
  • Order by date
  1. Corgas

    Managing Spares PSV

    Steam valve on Waste Heat Boiler (475 psig set pressure). Valve was tested in 2013 and sat on shelf for 3 years and it was put in service in 2016. Operator says it's not past due since it's been in service for only two years even though last test date was in 2013. Is it past due? has anyone...
  2. Corgas

    Flexsteel Piping

    Colleagues, How do you assess swaged connections integrity in a flexsteel line that has been in service?
  3. Corgas

    API 579 / ASME Fitness for Service

    Colleagues, Here in the USA, is it mandatory that a FFS assessment needs to be signed/approved by a PE (Professional Engineer)? If there's something in writing, I'd like to read it. Thanks,
  4. Corgas

    Positive Material Identification

    Hello colleagues, We are trying to sort out sheets that are supposedly made of BUNA N and FKM. Hardness shore A for both materials are very similar 70 vs 75. Is there another non-destructive method that we can use? Thanks in advance, Corgas
  5. Corgas

    Positive Material Identification for elastomers

    Hello colleagues, We are trying to sort out sheets that are supposedly made of BUNA N and FKM. Hardness shore A for both materials are very similar 70 vs 75. Is there another non-destructive method that we can use? Thanks in advance, Corgas
  6. Corgas

    UL 142 Tanks

    Came across two UL 142 tanks ( 650 bbls - cone roof) currently used to store slope oil. Just finished reading the UL 142 standard a didnt see anything on Lightning protection. DO they need to have lightning protection installed (as per API RP 545) even though these are not API tanks, Thanks...
  7. Corgas

    Piping Spacing

    I found following chart to determine minimum spacing between pipes and between pipes and structures. Can anyone tell me if this is based on any published standard or code? Thanks in advance, Corgashttp://pipingdesigners.com/downloads/PIPE%20SPACING%20CHART.pdf
  8. Corgas

    Metallic Flex hoses in ASME B31.3

    Hello, Can anyone tell me in which section of ASME B31.3 says that metallic flex hoses can not be used for permanent process piping? Thanks in advance, Corgas
  9. Corgas

    Flange Joints - Threads engagement

    In ASME B31.1 parag 108.5.1 : "Bolts and bolt studs shall extend completely through the nuts". Is there a similar wording in ASME B31.3? Thanks, Corgas
  10. Corgas

    ASME B31.8 for wellsite piping

    I've read thread 292-69658 and in that thread some members of this forum mentioned that they've used ASME B31.8. I went back and read again ASME B31.8 - 2010. According to 802.1(b)(6) flow lines between wellhead and/or separator traps are outside scope of this standard. This is also shown on Fig...
  11. Corgas

    PREN

    Colleagues: Can PRE numbers be applied to predict resistance to MIC (Microbiologically Induced Corrosion)? After all, Mo improves the passive layer. Is there a published relationship between PREN Vs resistance to MIC? Thanks, Corgas
  12. Corgas

    Stress Ratio & Impact testing

    Colleagues, After calculating stress ratio according to ASME B31.3 (2008 edt) Fig. 323.2.2B, General note (a)(1), number is well below 0.3 (it doesn't intersect curve). What reduction in minimum design temperature can I use? Thanks in advance. Corgas
  13. Corgas

    ASME B31.4 & HDPE pipe

    I just came across a piping spec which list HDPE pipe (PE3608) as the piping material. I checked B31.4 code and did not find any reference to non metals piping materials. Does B31.4 allows use of HDPE piping? Thanks, Corgas
  14. Corgas

    HDPE Vs Ethanolamine

    Colleagues, I need your help again. Gas from new wells with higher H2S concentration is requiring injection of H2S scavenger (ethanolamine). Pipe is PE 3608 (HDPE)and service is Dry Gas, low pressure (< 100 psi) and low temp (< 80 F). Before I get lectured, I have searched previous "threads"...
  15. Corgas

    Inspection Frequency

    This double wall tank storages H2SO4 and is made of HDXLPE (crosslinked HDPE). Wall thickness calcs were done according to ASTM D 1998. Is there a standard similar to API 653 for non-metal tanks? intention is to assign inspection interval and use some kind of "inspection checklist" similar to...
  16. Corgas

    Rx question

    I recently came across following : "On completion of welding the ring(s) shall be radiographed. Radiographic methods and acceptance criteria are specified in SP-1025, except that the position and description of all imperfections detected by radiography shall be reported." What's this SP-1025...
  17. Corgas

    ASME B31.8 Piping Spec

    I just came across a piping spec for underground Gas Pipeline - Sour Service (NACE MR0175/ISO 15156)designed according to ASME B31.8 -2007. Design temps are -50F to 140 F. Since I'm not familiar with B31.8 I started reading this document and on para 802.12 (b)it says: "This code does not...
  18. Corgas

    WAG Systems

    Do WAG piping systems fall under jurisdiction of ASME B31.8? Regards, Corgas
  19. Corgas

    Max allowable stress

    Colleagues, I need the max allowable stress values thru 500 F for : SA- 283 C & SA - 516 -70 Vessel was built in 1970 Thanks, Corgas
  20. Corgas

    Flame arrestor

    For a tank (400 BBL) built to API 12F type A (Flat), is it mandatory to install a flame arrestor? If it is, please indicate standard, code or recommended practice. Thanks, Corgas