  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. successwale

    Feedback voltage loss

    Can somebody tell me what might cause feedback voltage less than 1V which also leads to throttle valve position fault in TCG2020 MWM engine . How to rectify this?
  2. successwale

    DZR TDC SENSOR ERROR

    Please am running an engine MWM, Whenever i want to start the engine it keeps displaying DZR TDC SENSOR ERROR FAULT, Wht could be the causes of this error
  3. successwale

    DZR TDC SENSOR ERROR FAULT

    Please am running an engine MWM, Whenever i want to start the engine it keeps displaying DZR TDC SENSOR ERROR FAULT, Wht could be the causes of this error
  4. successwale

    DZR TDC SENSOR ERROR FAULT

    Please am running an engine MWM, Whenever i want to start the engine it keeps displaying DZR TDC SENSOR ERROR FAULT, Wht could be the causes of this error
  5. successwale

    Differential Current Fault on generator multi differential relay protection

    What might be causes of differential current on generator multi differential relay protection unit of MV panel. once the generator synchronized, carry a few a KW load it shutdown the engine on differential current on GPU.
  6. successwale

    TAVRIDA Vacuum Circuit Breaker Close and open immediately

    What might cause the TAVRIDA Vacuum Circuit Breaker 630A when closed, it opens back?
  7. successwale

    Generator overcurrent

    I am running a deutz gas engine of 1MW ,the engine do shutdown on OVERCURRENT, what can i do to rectify this fault?
  8. successwale

    Phase fault

    I'm running 3.5MW deutz gas engine of which the outgoing breaker 2MVA always trips on PHASE FAULT and EARTH FAULT. I don't know what i can do ensure this did not repeat it self. please could be the sepam setting causing this?
  9. successwale

    Negative sequence/ Unbalance

    What could cause a 11KV HV cct breaker to indicate UNBALANCE1 on sepam?
  10. successwale

    Differential Current

    iam running a gas generator of 1.5MW Duetz engine which indicting Differetial Current from the control panel.what might be the causes and solution to this problem?
  11. successwale

    Overpressure Crankcase

    I'm running three deutz gas engine with demand load of 1.845MW,one of the which is biggest 1.5MW suddenly drop on load due to overpressure crankcase.What might leads to this problem?