In Leung's paper "Venting of Runaway Reactions with Gas Generation" AIChEJ 1992, allowance can be made for reduction in design flow arising from mass depletion during the emergency relief process in bubbly flow. The applicable reduction factor is given as (Eq 39)
W/Wmax = 1/(1+ ao^.5)^2...