  1. humanengr

    New Concrete Pedestal to Existing Concrete Interface

    An existing concrete foundation will be surface prepped to placement of a new concrete pedestal. The concrete pedestal will support rotating equipment. Epoxy grout will be utilized at the top of the pedestal to support the equipment. The surface of the existing concrete foundation will be...
  2. humanengr

    Effect of Hydro-excavation on Drilled Pier Footing Design

    Checking if anyone can provide or point to a resource on considerations in the design of drilled piers when the excavation is hydro-excavated instead of auger-drilled. Any information such as potential reduction in soil resistance capacity would be appreciated. Would this normally be addressed...
  3. humanengr

    Retaining wall Reinforcement

    The vertical tension rebar in a retaining wall typically is anchored in the footing by having the rebar / dowel turn into the toe of the footing at or just above the bottom footing reinforcement (not turned into the heel). Can someone please provide an explanation of why it must be "turned" into...
  4. humanengr

    Maximum pedestal height and unspliced dowels

    Can someone point to a guide on how high dowels can extend above footing before they should be terminated and spliced, if the pedestal height is beyond that limit? This is from constructability view, not a design issue.
  5. humanengr

    Use of Shear Friction to resist one way shear in Footings and Pile caps

    I'd like to ask if anyone has utilized shear friction to resist one way / deep beam shear in footings or pile caps. The foundations are monolithically built. The one way shear (as opposed to punching shear) governs the design of the footing / pile cap. Rather than increase the depth of the...
  6. humanengr

    dyna5 / dynapile comparison

    I'd like to ask if anyone is familiar with the two programs, dyna5 and dynapile, and if you have comments regarding comparisons of the two programs, how similar would you expect results to be.
  7. humanengr

    Design Loads for Tower Cranes

    ASCE/SEI 37 Provides Design Loads for Structures during Construction. My questions is, are these loads applicable to tower cranes and exterior gantry cranes? It appears not, so what is the governing document for design loads on cranes in the US?
  8. humanengr

    Software Migration

    I'm wondering if anyone can share some experiences in migrating a relatively large organization from STAAD.Pro to RISA Suite. I'm curious as to pushback (resistance to change) difficulties in adjusting to RISA, and any software limitations in RISA vs. STAAD. RISA would be used primarily for...
  9. humanengr

    Precast Concrete Table-Top Machine Foundation

    I would like to ask if anyone has experience utilizing pre-cast concrete for a table-top structure supporting vibrating machine / compressor. My concern has to do with the joints (Beam to Column, and Top Slab to Beams). The joints will consist of grouted rebar sleeves. The grout is high...
  10. humanengr

    Support for duct bank encased in mat foundation

    I am designing a pile supported mat foundation that must encase an existing duct bank. The thickness of the mat above the duct bank is not sufficient. Otherwise, I would have ignored the thickness below the duct. So, I must rely on the thickness of the mat below the duct. Since the duct bank is...
  11. humanengr

    Non-Contact Lap Splice in ACIP Pile - Bar Spacing Exceeded

    I have a case where tension in the ACIP pile must be transferred from the rebar cage to a center bar which continues to the bottom of the pile. The rebar cage terminates approximately half way down the length of the pile. The spacing between the cage rebar and the center bar exceeds 6in...
  12. humanengr

    Existing Foundation Corrosion mitigation / repair

    I'm working in an area where existing foundations were specified to be constructed with Type V Sulfate Resistant Concrete with slag or pozzolan and maximum 0.4 water-cement ratio. The soil is highly corrosive and contains sulfates. Unfortunately the specification was ignored. Deterioration of...
  13. humanengr

    Beam - Critical Sections for Shear and Moment - Precast Concrete

    ACI 318-14 specifies the locations of the critical sections for beam shear and moment. These locations (d from face of support, and at face of support respectively) are conditioned on the beams being "built integrally" with the supports. I have some doubt as to whether the above would apply to...
  14. humanengr

    Eccentric Bending Moment on WT

    When calculating the moment acting on a WT due to eccentric axial load applied to the flange of the WT: Can I use eccentricity = Yp (distance to Plastic Neutral Axis, PNA), or is it required to use Y (distance to geometric neutral axis ?
  15. humanengr

    Effect of coating on Steel Piles

    I'd like to inquire if anyone can advise on whether the external coating on steel piles would have an effect on the skin friction and the performance of the pile. In this case the production steel piles may be galvanized or epoxy coated. Would pile tests using uncoated steel have a material...
  16. humanengr

    API 5CT - K55 for structural purposes

    Just checking if anyone has seen API 5CT- Grade K55 used for structural purposes. (Steel piles in this case). The chemical composition table (Table C.4 in API 5CT) does not list any limits (max. or min.) for any elements other than Phosphorous (P) and Sulfur(S). Without a max./min. on critical...
  17. humanengr

    API 5CT-Gr. K55 structural properties.

    Just checking if anyone has seen API 5CT- Grade K55 used for structural purposes. (Steel piles in this case). The chemical composition table (Table C.4 in API 5CT) does not list any limits (max. or min.) for any elements other than Phosphorous (P) and Sulfur(S). Without a max./min. on critical...
  18. humanengr

    ACIP-D (Displacement ACIP Piles)

    I am considering the use of ACIP-D piles in lieu of "standard" ACIP to reduce the volume of spoils (excavated soil). Would like to inquire if anyone has had some enlightening experience with ACIP-D. In particular: How much reduction in spoils can be expected? What are the different types of...
  19. humanengr

    Weld Directional Strength Increase and Strain Compatibility

    Section J4 of the AISC Specification for Steel Buildings (AISC 360-16) provides equation J2-5 to account for the weld directional strength increase. This increase factor may be applied; "IF STRAIN COMPATIBILITY OF THE VARIOUS WELD ELEMENTS IS CONSIDERED." I believe the stipulation regarding...
  20. humanengr

    Eurocode - Structural Analysis-Design Software

    Checking to see if anyone has experience using RISA 3D or STAAD with Euro Code for Re-Concrete, CMU, Steel design? My question is do these software systems provide accurate results with respect to Euro Code design?