  1. chorner26

    Settlement of supports on 2 span beam Formulas

    Where do I find the stress formulas for deflection of a center support on a 2 span beam, and or a beam with two un-equal spans. (See attached sketch) for clarification.https://files.engineering.com/getfile.aspx?folder=bf9a89af-a2fa-4956-94b2-f09b159a64b7&file=scan1872.pdf
  2. chorner26

    Components & Cladding of a Vertical Fin attached to a Curtainwall Mullion

    thread176-146176 I have further question about that is reference to the thread above. I have a 20' tall vertical wall mullion that has 5'-0" of perpendicular wind tributary (Say 25 PSF Net Service- in any direction). The Vertical fin has a nosing projection that projects 2'-0" off the vertical...
  3. chorner26

    Confusion from the ASCE 7-10 and CBC 2019 Wind Code

    OK so I have always multiplied out the wind loads from ultimate and multiply by CBC (equation 16-33 on page 23 of the CBC. ie if the wind pressure is 25 psf ult *Squareroot(0.6) = 0.77*25psf =19.25 psf. But the confusion comes when applying ASCE 7-10 load combination 6 ____ D+...
  4. chorner26

    Calculation example for a 1 sided threaded stud in to a plate

    Lets say I have a 3/8" diameter threaded stud with a nut on one side, going into a 1/2" thick 36ksi steel plate. How would I calculate the capacity. Plan checker says AISC only addresses a nut or mushroom head on both sides.
  5. chorner26

    What is the cut off point to use Appendix D Ch. 17 ACI 318-14 (18" or 24")??

    If i was designing a 24"sq x 48" tall light pole base of 3000 psi concrete, At which point can it ignoring appendix d and just use reinforced concrete design with tension reinforcement and and shear stirrups. IS is 18" or 24" inches or is there a specific code section that I can point to on...
  6. chorner26

    Using a factor Vu = 1.67 ASD for concrete (Wind) to convert between the two?

    Where is this described in the ACI 318-14? I'm using wind for design thus I've always used used 1.6 times Wind to go from service level to Ultimate level loads for wind. Is there a footnote that I am missing somewhere.
  7. chorner26

    SBEDS Software or blast Mitigations Software

    What programs are people using? I have seen peopl using SBEDS X1.1.1 but that seem pretty old. I am fine with that, does anyboy ahve a link to software to purchase or any info. to help a guy out?
  8. chorner26

    Wood Blocking for Shaft walls, Can I do this for fire rated Assembly?

    The use of wood blocking inside of elevator shaft walls. or to attached hand rails in fire assembly rated walls. Is their a coded exemption where I can do this. I read it at some point but cannot find it.?? This is for a metal stud assembly.
  9. chorner26

    Empirical Design of a plain concrete wall

    So it seems you can design a plain concrete wall with no account for reinforcement. My question is the use of Phi Factors. The commentary is ACI 318-14 states to use the same Phi factors as reinforced concrete [R14.5.1.2] Pg. 199 but [table 21.2.1 } - Pg. 341 has value of Phi = 0.6 for plain...
  10. chorner26

    How to Calculate Sxc of unsymmetrical shapes

    Guys, I have struggled with this in the past but here is a great examples from the ADM 1-2015 (Enjoy!)https://files.engineering.com/getfile.aspx?folder=e428cfca-29dc-434a-a940-437a9e4a24bb&file=Sc_Calcualtion_on_Unsymmetrical_Shapes.pdf
  11. chorner26

    SE Exam Specification and Passing Criteria

    I recently took the Gravity SE exam and received 3 acceptableness and 1 not acceptable on the afternoon portion of the exam. It gave me an acceptable in Concrete which I barley drew pictures and diagrams for. (Ran out of time) It gave me unacceptable on Steel which I completely smoked. However...
  12. chorner26

    Design Guide to Concert Precast Post bases.

    Are there any design guide or data on how to size a precast concert post base for deck in California. Yes I know how to size footings, but can't find anything on this.
  13. chorner26

    How do I calcuate a circular concrete column or a circular concrete footing?

    My footing is 3'-0" embed into the soil and had a gravity load of 1000# and a lateral load of 400# at 8"-0" above its centroid (or 3200 ft#) Do I assume a equivalent cross section for a square shape? Ie 2/3H a and Width. this is a short concrete column. Thanks
  14. chorner26

    Cantilever screws at 1/2: stucco Gap

    Does anybody have a good design example of bending of a screw at a stucco gap. I've always calculated fb= v/a+ M/S for a reduced circular section, which very rarely calculates for anything less than a 3/8" anchor. Commonly contractors want 1/4-20 screws, any advice on how to make it work? Thanks
  15. chorner26

    Plate Washers for Sill plates- 0.299x 3" X.3" Galvanized - 2013 CBC

    Where is this reference in the California Building Code 2013? My contractor installed 2 1/2 x 2 1/2x 1/4" which is all they sell at home depot. I'm trying to see if I can work around the code.
  16. chorner26

    Attachment to HolllowCore Planks for Appendix D??

    it there are post installed fastener that I can get some sort of values for to attach to? Say for 300# service load shear. I am in California thus Cracked Concrete is a concern.
  17. chorner26

    FIre Damaged 2x6 - Any Alloable Values??

    I inspected a fire damaged house today and recommended they replace all the fire damaged or even smoke damaged timber for Roof Rafters and post, but my question is, are there any guild lines (FEMA or NDS), that I could even calculate an allowable bending value or tensile value of burned wood...
  18. chorner26

    Where in the CBC 2013 Does it State What a Civil Engineer can deisgn vs.a Structural?

    I'm considering starting my own company but at least 40% of my work is DSA and OSHPD thus not sure if the time is right. I'm sure tired of making other people rich. Can I design a component of a "SE" required building. Ie 4 Stories or more, schools, hospitals. Thanks.
  19. chorner26

    Perforated Shear Walls Used to be in 2007 CBC -California Building Code Table 2305.3.8.2 on page 315

    Where did this chart move to in the 2013 CBC? Thanks
  20. chorner26

    1/3 Stress Increase has Disappeared or Moved again in 2013 CBC

    OK, so I'm doing a glass guardrail design and: in the 2007-2010 CBC. (1607.7.1.3 on Pg. 10 . I can use a 1/3 Stress increase. Now, for CBC 2013, it has disappeared. 1607.8.1 (pg.12) My question is where did it go, is it buried in a handrail designer association manual or somewhere in the ASCE...