  1. RalphChristie

    CT Magnetizing current

    Hi After a discussion I've realized I had a lack of knowledge on CTs - any specifically on specifying the magnetizing current of a Class PTX (X) CT, thus an CT been used in the IEC-world. In a class X CT the performance is defined in terms of a knee-point voltage and the magnetizing current at...
  2. RalphChristie

    Substation authorization

    It is my responsibility to declare people authorized to do work in substations on our mine. Normally it is not a problem, the persons working in the substations is qualified electrical artisans, they do get some training on the safety, the relevant procedures, the operating principles, the...
  3. RalphChristie

    CT explosion

    We've had a CT explosion last week on one of our 66kV-lines, worst I've seen. Investigation still going on. Many of you have probably seen similar incidents before, but I thought it would just be interesting to show/share it. Porcelain pieces were laying in a radius of approx. 50 meters...
  4. RalphChristie

    Making files available for download?

    How Do I Make Files Available For Download? ... No Emails Required This is a FAQ written by CorBlimeyLimey: FAQ559-1177 See also thread559-138321. He can't collect stars anymore, but we still can rate his FAQ. I think it is excellent written idea/FAQ.
  5. RalphChristie

    Time-delay between starting of multiple motors

    I have asked the question in the Electric motors & motor controls engineering Forum: See the original question in thread237-136811 I would appreciate it if anyone can give his/her comments on the time-delay between two or more motors during start-up (for a conveyor) from a mechanical...
  6. RalphChristie

    Time-delay between starting of multiple motors

    I have a question regarding the starting delay between two or three motors driving the same load. In my case it is three motors driving a conveyor. It is 3.3kV, 500kW slipring motors (WRIM) and each one is started with a vapourmatic(liquid) starter with three steps. On the third step the rotor...
  7. RalphChristie

    Connecting copper and aluminium conductors

    Any recommendations, methods, type of connections, etc. on connecting copper and aluminium? (380V to 66kV) I am looking for advice on: :overhead conductors, (copper lines to aluminium lines) :aluminium cables on copper overhead conductors, :copper cables on aluminium overhead...
  8. RalphChristie

    Biggest Tsunami recorded

    http://www.extremescience.com/BiggestWave.htm Our prayers are with those in the disastrous areas. Ralph
  9. RalphChristie

    Soares Book on grounding

    Can someone give me some comments on this book, especially between the 1st edition and the 8th edition? I want to buy the book, but read somewhere the last edition is not that good. Is it beter to look/search for the first edition, or can I buy the last edition? Thanks Regards Ralph
  10. RalphChristie

    NEC (zig-zag trsf) temperature trip

    We have 2 Yd1 transformers in parallel. (20MVA, 66/11kV each) The secondary side of each transformer is earthed with a NEC. (zig-zag transformer, 400A, 10sec) Our problems start with earth-faults on the downstream feeders. Sometimes, when a fault occurs, the NECs trip on top oil temperature...
  11. RalphChristie

    Sensitive earth fault protection - medium voltage

    I've got a protective issue question, I'll appreciate it if anyone can help me or point me in some direction. With a high impedance grounding system (secondary of trsf grounded through resistors) in a medium voltage system, on what kind of earth fault protection does IEC insist? (I'm looking...
  12. RalphChristie

    Sensitive earth fault protection - medium voltage

    I've got a protective issue question, I'll appreciate it if anyone can help me or point me in some direction. With a high impedance grounding system (secondary of trsf grounded through resistors) in a medium voltage system, on what kind of earth fault protection does IEC insist? Is earth fault...
  13. RalphChristie

    Flashing in WR Motors

    See also thread237-53974 We are experiencing heavy overflashing problems on our 500kW slipring motors (WRIM) in our plant. The plant have a lot of conveyors, the drives on the conveyors varies between 1 to three drives per conveyor. There is no spesific drive or conveyor that gives no problems...
  14. RalphChristie

    OLTC

    Dear all Is there any difference between a master/slave configuration and a master/follower configuration for OLTC's (onload tap changers) on parallel transformers, or is it the same? If there is a difference, what is it, and why do they use it? Many thanks RCC
  15. RalphChristie

    Overload through-fault protection curve for a zig-zag trsf

    Hi I want to draw the overload through-fault protection curve for a NEC. (zig-zag transformer, earthing transformer) The continious line current rating of the NEC is 60A, the short time line current rating is 400A for 30 seconds. Is there any way how I can plot this curve for values more than...
  16. RalphChristie

    Buchholtz relay

    With what type of gas does you test a Buchholtz relay on site? - Nytrogen? Thanks RCC
  17. RalphChristie

    Lightning problems

    We experience trippings (instantaneous) on some of our 66kV-transmission lines due to lightning. Each tower consists of two wood-poles with two earth/ground conductors on top. Next to each pole there runs also a earth conducutor - this conductor is connected to the overhead conductor and...
  18. RalphChristie

    Slipringmotor's grid resistance

    We have a 3ph,70hp slipringmotor been used on a bending machine. Stator V - 400V Stator I - 107A Rotor V - 288V Rotor I - 113A Speed - 575rpm The motor is conected via an old type drum controller (forward and reverse) to a grid. Normally, when the operator of...
  19. RalphChristie

    CT choice for transformer feeder

    What are the rules of thumb to choose the CT-ratio of protection CT (O/C and E/F) on a feeder in a substation? I've seen CT's with a low ratio, but the faultlevel on that point is very high. The faultlevel of our 20MVA, 66/11 kV Trf is approximatly 12kA. The 11kV Incomer have a ratio of...
  20. RalphChristie

    Fault current

    On a single transformer, to determine the fault current on the secondary side, you can use the following simple method: Short-circuit MVA = (100*P) / X% Fault current = Short-circuit MVA / (1.73*Vsec) My first question is: What will happen if two or more transformers is in parrallel(assume...