Does anyone have suggestions for ACS355 VFD that intermittently faults on overvoltage?
At the time of the last fault voltage was 831 volts. This fault is happening once every couple of days.
What is the lowest temperature you could measure if using a ammonia refrigeration system?
If you have any references they would be much appreciated.
Thanks
I would like to see the inlet to an evaporator coil. The coil is in a dark, sometimes wet and generally inaccessible location most of the time. The intent is for operators to know if ice is building up on coil.
Does anyone have any product recommendations?
If you had 2 companies offering you different positions at about the same compensation.
Company A was in a strong financial position and a market leader and you would have more of a field role.
Company B is in a weaker position financially.But they are asking you to come and be a...
What should you do with the VSD cable shield wire at a motor disconnect?
My intent was to join earth ground and shield at motor and VSD. But I am not sure what to do with shield at disconnect.
Thanks
I have 8 VFD's that are going to be controlled via Hand Off Auto switches.
Is it "better" to use a external 24dc power supply for start circuit?
Or should I use each VFD's supply?
The VFD's will be mounted adjacent to each other and have a common stop button(via relay).
VFD Powerflex 4 22A-D6P0N104 Fault code 6.
Motor 2 HP runs across the line when bypassing VFD(because of fault)approximately 1.7amps all 3 phases even when motor is loaded.
VFD can start motor unloaded(empty conveyor). But after starting conveyor fills with product amperage climbs up +11 amps...
I want to read the level of a water in a polytank. The water fills the tank via gravity from a condenser on a roof(lots of turbulence and vibration).
Can anyone recommend a level or pressure sensor with a 4/20mA output for this application?
Thanks
I would like to start and stop a PowerFlex 40 with a 4/20ma signal.
Can this be done?
Is it a bad (stupid/won't work/troubleshooting nightmare )idea to use the PowerFlex40 24vdc internal power to source transducer?
Thanks
I have a AB bulletin 100-C Contactors pdf. http://www.ab.com/en/epub/catalogs/12768/229240/229254/229461/229481/tab6.html
I am trying to intrepret the Coil Consumption data for an AC contactor.
For instance |50hz,60hz,50/60hz | Pickup |[VA/W]| 35/32 |
Does the VA rating correspond to 50hz and...
I have a 1600A panelboard that is fed via a 2500kva transformer that is rated 480/277v on the secondary.
The panelboard does not have any loads that need a neutral.
Is it required to run the neutral conductor from the X0 of the transformer to the panelboard to satisfy NEC?
Thanks
I have a blower fan Motor:20hp, 460, 22fla, 1.15sf, codeJ
DesA,ClassB.
The ABB ACS350 VFD controlling fan motor is occasionally faulting on a overcurrent.
It faults when automatically starting from a dead stop.In the fault history I can see the current at 51 amps. The drive is then powered...
If I took a 5 gallon bucket of ice with a core temp of 0 degrees Fahrenheit and moved it to a room with a temperature of 36F how long would it take for the core to warm to 36F?
Is there a equation/rule of thumb/website you could direct me to?
Thanks
I had (13) 20hp,480volt 3phase motors running at the same time . The 480volt feed terminates at a tap block which then feeds fuses for each motor, contactor and ol's.
15 fuses feeding 5 motors blew.
That left me with 8 motors running.
Only 1 of the 5 motors was identified with a problem no...
I need a sensor that can detect if a bag filled with commodity(fruit) is sealed.
The bags will be moving at a rate of about 100 per minute on a conveyor.
Does anyone have any suggestions?
Thanks
I am using a 3 wire 120vac prox switch as an input to a micrologix plc. The input is dropping out(indicating light flashes off then back on erratically). If I wire the prox directly into the plc bypassing all the field wiring the input responds the same way.
Is a resistor the answer?
I have a package unit with a panelview plus HMI and compact logix plc. What I would like to accomplish is add 40 I/O points,compact logic plc , and capability to see on existing HMI + 1 new remote PC.
I have used RSview on a PC before but I don't have much experience with Panelview plus. My...
I had a 3000 amp 480 volt breaker trip on a Ground Fault. The Hmi for the ground fault showed 79Amps. I did find a 36kw heater with all 3phases grounded. It was fed with (3) 50a LPJ fuses. 1 of the fuses was blown.
In the future I would like fuses to open before tripping the 3000 amp breaker...
Hello,
Would anyone be familiar with a Elon EPW-AZ-24DC?
It has a 24volt coil dc , 2 sets of contacts and a input from a plc.
I have googled it with no success and am waiting on a email from the machine manufacturer . I do know that when terminals A1 and A2 have 24dc supplied the contacts...
Hello,
I wandered over here from the Electrical side. I am looking for help with understanding the control of submersible pumps, in order to possibly modify plc code or recommend something else. The system I am working with has 5 pumps all supplied by vfd's. The pumps are trying to maintain...