Hi all,
Can you explain why for aboveground flammable horizontal storage tank Emergency vent sizing considère an allowable over pressure of 35 Kpa (5 psig)in ULC S601, while in NFPA 30 Emergency vent sizing consider only 17 kpa(2.5 psig)?
Also normal maximum operating pressure in ULC S601 state...
Hi All,
I'm designing a small tank with Flat Bottom ( less than 10 ft Diameter) at more 10 psig Presuure design,
So I know API650 is applicable only for max 2.5 psig, and API 620 is for large tank (typicaly more than 300 ft),
the question is can I use API 620 for this small tank?
Thanks.
Reg...
Dear All,
I'm designing a special Manway for coded Vessel ( ASME Section VIII Div.1), my question is very simple : Can I use plate (SA-240-304 for example), for this attached manhole cover, which is fabricated from one machined piece, or it's mandatory to use only forged material?
Thanks...
Dear All,
I'm designing a Stainless steel Small high pressure vessel (650 psig Pressure design at 250 oF), with conical shell :Top Dia.8in Id, Btm Dia.2in Id, H=20in , thk= 5/16 in, So We are not able to form this conical shell, my question:
what is the ASME Section VIII Div.1, requirement , if...
Dear All,
I'm designing a 20in Dia. flanged manhole as per Appendix 2 ( ring type loose Flange + flanged Dished cover) see attached (2) sketches , and I have some confusion about material flange specification , so my question is very simple:
as theses flanged are not hubbed flanges, nor reverse...
Hi,
I have some confusion in understanding the required material for this flange ( see attached drawing) regarding
ASME Code : App. 2-2 (d)(1): "Hubbed flanges may be machined from a hot rolled or forged billet or forged bar….."
App. 2-2 (d)(2): "Hubbed flanges [except as permitted at (1)...
Hi,
I am having some trouble to calculate reinforcement according to UG-37 on ASME F&D head opening for conical nozzle as shown on the attached drawing . ( as you see the nozzle is not cylindrical).
any help will be very appreciated
Thanks.
Laurent...
Hello ,
I have simple question, as ASTM 270 is not on the ASME Sect II Material list, I suppose that I can't use it in ASME job ,So, which SA material can substitute ASTM 270 sanitary tubing ?.
thanks.
Laurent.
Hi,
I have to design a 45 000L of Ethanol (95% alcohol) tank,to be installed outside,
for sunny days, we have to insulate the tank.
What is the requirement of the insulation ?, I have checked NFPA30.
Thanks for your help.
Laurent.
Dear All,
I'm looking for the right live design loads per OSHA for designing walkway ans platform for industrial site.
there are sevel rate,40 60, 100 psf, I'm confused and I like to be sure to use the good rate with OSHA reference.
could you help please.
Thanks.
Laurent.
Dear All,
I'm looking for the right live design loads per OSHA for designing walkway ans platform for industrial site.
there are sevel rate,40 60, 100 psf, I'm confused and I like to be sure to use the right rate with OSHA reference.
could you help please.
Thanks.
Laurent.
Hello ,
I'm having trouble undertanding which material can I use for Flat Flanges witout hub regarding Appendix 2 ou UG-14.
so my question is very simple : Can I use flat plate for theses flanges like studded outlet shown on thoses attachements
(flane on btm head , anf flange on top head)...
Hello ,
I'm having trouble undertanding which material can I use for Flat Flanges witout hub regarding Appendix 2 ou UG-14.
so my question is very simple : Can I use flat plate for theses flanges like studded outlet shown on thoses attachements
(flane on btm head , anf flange on top head)...
Hello,
I'm sizing the vent for vacuum tank in condition of cold spray after hot washing, Could any one help please giving the formulas for this calculation, the aire venting and the air inflow required, in order to size the vacuum valve.
the data given is: MAV(Maximum allowable vacuum)for the...
Hello,
I'm sizing the vent for vacuum tank in condition of cold spray after hot washing, Could any one help please giving the formulas for this calculation, the aire venting and the air inflow required, in order to size the vacuum valve.
the data given is: MAV(Maximum allowable vacuum)for the...
Hello,
I'm sizing the vent for vacuum tank in condition of cold spray after hot washing, Could any one help please giving the formulas for this calculation, the aire venting and the air inflow required, in order to size the vacuum valve.
the data given is: MAV(Maximum allowable vacuum)for the...
Hi,
I have to size Anchorage for vertical tank on 4 legs, for which only seismic loads govern ,after calculation per IBC code, the seismic moment is 145 kips ft, and the seismic shear is 8 kips.
As the BC anchors is 96 in, the tank height is 30 ft, and the total tank weight is 160 kips...
Dear All,
Could you help me please to design Nozzles shown on this attached schema.How can I can calculate or check wall thickness and may be reiforcement need for each situation Pb1, and Pb2 as per ASME Code Sect. VIII div.1?
Pb1: clamped flange on Conical Btm Head (Outlet Btm valve body)
Pb2...
Hello,
On the Bottom of ASME 2:1 Elliptical Head, I have to design a 12.6" ODX 8.66" ID X 0.7" thk Studded flange with 8 x7/16" dia. whole holes ( none threded hole)in order to install a Europpeen Agitator.
The tank is designed as per ASME Section VIII div.1.
I'm using Compress Programe for the...
Hellow,
On the Bottom of ASME 2:1 Elliptical Head, I have to design a 12.6" ODX 8.66" ID X 0.7" thk Studded flange with 8 x7/16" dia. whole holes ( none threded hole)in order to install a Europpeen Agitator.
The tank is designed as per ASME Section VIII div.1.
I'm using Compress Programe for...