  1. MAPower

    Measuring/Calculating Boiler Feedwater Heater Performance at Startup

    At our coal fired facility we recently replaced four of six feedwater heaters. With the recent replacement I must measure/calculate the new heater performance. I will need to do this for startup conditions of which I do not have all the desired measured parameters needed to calculate TTD...
  2. MAPower

    Calculating Volumetric Flow Using Motor Sizing Formula

    Hi, I'm trying to get some help doing a rough estimate calculation of the volumetric flow through and induced draft fan on a balanced draft unit without doing a performance test. Here is the data that I have available to me in our historian: - fan inlet & outlet pressures - fan inlet...
  3. MAPower

    Calculated Volume Flow Through ID Fan?

    Hi, I'm trying to get some help doing a rough estimate calculation of the volumetric flow through and induced draft fan on a balanced draft unit without doing a performance test. Here is the data that I have available to me in our historian: - fan inlet & outlet pressures - fan inlet...
  4. MAPower

    Cleaning Options for Feedwater Heater Steam Supply Line

    I was looking to see what reccomendations/options anyone had on cleaning a new steam supply for a 1st point feedwater heater after construction. I have been looking at some startup documents, but no good information is available for feedwater supply lines (lots on main steam line "steam blows")...
  5. MAPower

    How to Determine Superheated Ammonia Vapor Density?

    How do you determine the vapor density of superheated ammonia vapor at the following conditions: - pressure = 15 psig - temperature ~ 130 deg F
  6. MAPower

    Vacating Ammonia Pipeline of Nitrogen Gas?

    I have a startup situation which is quite puzzling: A ~10 mile, 4 inch anhydrous ammonia pipeline supplies ammonia to our plant process. The line is ~4 foot underground throughout except where it crosses under rail crossings and in two locations where it goes under river. Initially, the line...
  7. MAPower

    Excessive Pressure Drop in Pressure Reducing Valve

    I have a Fisher 627WH pressure regulator, used in anhydrous ammonia service. This valve was originally going to see up to ~750 psig and drop it down to 300 psig, but now is only seeing about 150 psig. I am seeing excessive pressure drop across it, ~100 psig! It doesn't make any sense, the valve...
  8. MAPower

    Periodic Functional Test of Anhydrous Ammonia PRV?

    Are there any codes that dictate periodic functional testing of anhydrous ammonia pressure relief valves? I have checked ANSI K61.1 and the only requirement is for visual inspection. The vendor (Anderson Greenwood) also does not have a recommendation. The valves will be replaced every 5 years...
  9. MAPower

    Anhydrous Pump Maintenance for Infrequently Used Pumps

    I have a Corken side channel magnetic drive pump used as backup to main ammonia supply pipeline. The pipeline is very realiable, maybe only one outage annually for about 6-8 hours. Our pumps are used to transfer anhydrous ammonia from tanker truck to our process at low flows. Beacause it is...
  10. MAPower

    Analyzing Potential Overpressuring by a Pump

    Hi, I've been asked to review if a particular pump can overpressure a piping system. The piping system is 300# class and the pumps are centrifugal type pumping anhydrous ammonia. What are the different things I need to look at? Is it just shut-off head? Or do I have to look at the pump curve...
  11. MAPower

    Vaporization of anhydrous ammonia?

    I have a water bath type ammmonia vaporizer in which the required supply ammonia operating range is 180 - 240 psig. The water bath temperature is set at 180 deg. F. The vaporizer vendor only wants single phase liquid ammonia being supplied to their equipment. I may need to bypass booster pumps...