Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: OUe
  • Content: Threads
  • Order by date
  1. OUe

    Horizontal Joint Reinforcement in SDC D, MSJC 2011, Special Reinf Masonry Walls

    I'd like a consensus on whether horizontal joint reinforcement is used in SDC D,E,F for special reinforced masonry walls. I am a senior structural engineer and work for a jurisdiction performing plan review in Oregon. Many times we get designs from back East and I am questioning whether a...
  2. OUe

    ACI 318 21.9.5.1 vertical rebar considered "effective" or can they be non-continuous betwe

    When I read ACI 318-11 section 21.9.5.1, I read that all vertical reinforcement must be considered effective in the sense that the vertical bars shall be relied upon for shear in two directions. I also understand this to mean that all bars shall be considered effective for the purposes of...
  3. OUe

    when does a finite element analysis become labeled "nonlinear"

    I tend to think of a nonlinear finite element analysis as "nonlinear" if it is a time-history analysis or dynamic analysis. I am a structural plan reviewer for a west-coast jurisdiction. I am the only engineer. The plans I'm reviewing are of a 2nd order magnified moment analysis of columns...
  4. OUe

    Metal Deck Flexible Diaphragm with Cantilever

    I have a 36 foot cantilever on a verco HSB-36, 20 gage roof deck. The depth is approximately 72' for a medical center here in Salem, OR. It is controlled by seismic design. The engineer I'm debating with on this says that the diaphragm is considered flexible under 12.3.1.1 of the ASCE 7-10...
  5. OUe

    Unistrut P1000 (or other) esr report

    I'm working on a project in Anaheim, CA involving cable trays and unistruts. My boss, the structural principal at our firm, recently mentioned that we should mention the evaluation report since it's in California. Well, this put a monkey wrench in everything I was doing. Not only has this...
  6. OUe

    re-entrant corner drag strut offset from corner

    I am performing a peer review of a qualified SE's work whereby he designed a re-entrant corner drag strut / collector beam offset about 4' from the actual corner of a tilt-up building. I have never seen this done. It would be my understanding that the collector/drag strut would need to fasten...
  7. OUe

    rho factor for modal analysis procedure

    Do I use rho if the dynamic analysis falls between the elf and elfxrho? ie: Vmodal = 137 kips Velfxrho = 167.4 kips (rho=1.3) velf = 128.8 kips I'm a little new to dynamic analysis with section 12.6 of ASCE 7-10, so any corrections/comments are welcome. I'm using RISA.
  8. OUe

    crane runway beams - differing adjacent spans, mid-span splices

    I'm designing a top-running bridge crane's runway beam and gantry tower support system. The bridge crane spans 94', the gantry towers (triangular lattice tower) span 25', 16', and 24'. Because I haven't designed a crane system in nearly 4 years, I am a little rusty. I have a radio/cab...
  9. OUe

    AISC Design Guide 25

    I am analyzing an ordinary moment frame of steel using the AISC Design Guide 25. I had built extensive spreadsheets to calculate stress ratios from the AISC 9th edition, appendix F, and am now getting familiar with the new design guide. I am currently struggling to find the understanding of...
  10. OUe

    Metal Bldg Design using RISA 3D

    Has anyone used RISA 3D for the analysis of a metal building? I am having trouble figuring out if the AISC 13th edition is ok to use? Where does the AISC address web tapered members for axial load + flexure? The last I used RISA 3D for a metal building analysis was with spreadsheets that...
  11. OUe

    SCBF - Magnified moments and Maximum force delivered

    I'm trying to design my columns for SCBF's and I was wondering if I need to use the combined loading effects of chapter H utilizing the Pmax determined by the RyFyAg of the brace. I have an inverted V-type brace at the roof level, which yields a huge beam at the roof level. The AISC 341-02...
  12. OUe

    Discontinuous walls and length of cantilever?

    Hello all, I am new to designing with wood construction. I am a PE and consider myself at a reasonable knowledge of designing the theoretical applications of wood structures. However, there are a few things that I'm still concerned about at my place of employment: there are times when other...
  13. OUe

    Composite Beams and rigid diaphragms

    This is my first post on this website, so please be kind. I am starting a new job on Monday, May 14th, and I'm being told that I will be working with my supervisor on a 3-story, composite beam, concentrically-braced frame of steel system for an office structure. My experience level is...

Part and Inventory Search