We are trying for Aerospace qualification for resisatnce welding and the testing that we have done so far has all been positive. The problem is we need to be able to do the section testing in-house, hourly per customer requirements. It would be insane to attempt to run production without having...
Looking for some feedback. We've successfully been GMAW welding A36 and A500 to SAE 1030 cast steel using ER70-S3 both CV Spray and modified pulse spray. Asides from the basic WPS parameter controlls we try to stay away from specilize control such as pre/post heat to save cost and training...