To all;
I am seeking some help. I have designed out a small subdivision and placed my catch basins a part based on a past design requirement that I learned. Well, the local authority wants the CBs every 400 ft which seems a little far for my design application. I have been using the Federal...
I have taken over some new responsibilities at work that I am really excited about. I have the groundwater remediation projects now and I am having to re-learn applications that I have not used in ten years. Anyway, I was looking at models that we have used but some of them seem outdated. Has...
I have taken over some new responsibilities at work that I am really excited about. I have the groundwater remediation projects now and I am having to re-learn applications that I have not used in ten years. Anyway, I was looking at models that we have used but some of them seem outdated. Has...
To anyone;
I am not that versed in the art of grading but we had an engineer that quit our firm. Anyway, we had a project that he did and the grading contractor is asking for the control points on the grading plan. I was asked to look at the layout and he specified spot elevations throughout...
Civil Engineers;
Have any of you ever had an architect or any other profession change your drawing in the field and build to it without contacting you? If so, what kind of liability do I have on the project? I had a design that I completed for site grading, drainage and retaining walls and I...
Has anyone ever used the EPANET program? I have been contacted to look at a distribution system and I am trying to learn this program. I was thinking about buying the Hastead WaterCad program but wanted to know pros and cons for both of them. Any recommendations for other programs? That...
To all;
I am looking for some guidance on weather I am just being hard headed. I am presently working on a medical center that will have a parking area under the building but will be kept to existing elevations. In other words the building will be raised and parking will be underneath. I...
I have been working on small projects lately and trying to best fit the WinTR-55 program to my projects. I am kind of new to the stormwater drainage application projects and trying to learn as much as I kind. I have found myself a little dazed by the inaccuracy or differences in program...
Have any of you been running into the acceptance of pervious concrete being accepted as an alternative means for storm water runoff? Or a better way to ask this, are any of you seeing this as an enhancement to a storm detention area when you do not have space available that might be required...
To all;
I have a quick question. I have a design that the architect presented to me. He has designed a hospital that will be raised and is in the form of the letter T. The parking underneath the top portion of that T I have been able to maintain 1.5% to 2.0% slope to catch basins. However...
I had posted a question about Fire Hydrant Flow a little while ago but I have another design question. Let me refresh my first post. I have a subdivision that is being designed by a local architect and land developer. The subdivision is small of only 11 homes with no expansion and it will be...
I am working on a water distribution line for a small subdivision of 11 homes. The architect has been working with the municipality and they have asked for a 6" DI line to the fire hydrant. I was planning on designing the line to the fire hydrant with a 2" blow off assembly for dead end...
I have a quick question about E&O insurance and having the insurance for part time work. I have a full time job at a company but at times I have the opportunity to do some work for a friend of mine when he needs some Civil and Environmental Engineering work done. I talked to an insurance agent...