See 5.3.2 in the new code.
for "Protection Against Local Failure":
"The sum of the local primary membrane plus bending principal stresses" are compared to 4*S.
Whenever working with membrane stresses and ANSYS, I have used PLSECT to get the membrane stresses ACROSS A SECTION. Has anyone...