Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: STR04
  • Content: Threads
  • Order by date
  1. STR04

    Flexicore Load Tables (Non Prestress vs Prestress)

    I'm reviewing a Flexicore roof dated 1959. I found a load table from 1954 and compared this to a 1971 table. See attached links. The steel ratios are much higher for the 1954 compared to 1971 which leads me to believe they earlier are not prestressed and the latter is. What is everyone...
  2. STR04

    Semi-Rigid Diaphragm for Metal Roof Deck (Round 2)

    thread1419-348348 Josh - I'm curious if RISA products have made any improvements/changes in their semi-rigid diaphragm analysis since your last response? TIA!
  3. STR04

    NCEES SE Practice Exam mistakes?

    I found this post so and it didn't answer my question so I probably need some clarification on this one. http://www.eng-tips.com/viewthread.cfm?qid=383898. This is in regard to problem #120. I was curious as to why the author did not apply AISC eq (4-1) to solve for an equivalent (KL)y_eq...
  4. STR04

    2012 6th Ed: AASHTO 3.6.1.3 - Applications of Design Vehicular Live Loads

    I noticed where in two separate example problems where the max moment was either 1) multiplied by Strength Level 1 Load Factors from Table 3.4.1-1 with impact for a simple span or 2) multiplied by the 90% of the effect of two design trucks per 3.6.1.3.1 for a multi span condition. So my...
  5. STR04

    SE Online Review Course

    I see one offered by Kaplin and by ppi2pass. Does anyone have experience good or bad with either program? TIA. http://ppi2pass.com/se-live-online-course-vertical-lateral-forces.html https://www.kaplanengineering.com/se-exam
  6. STR04

    Bentley Support for STAAD Pro

    I'm not getting any warm and fuzzies on this? Engtips is much easier to navigate than Bentley forums...ugh. Does anyone have tips for support. TIA.
  7. STR04

    Physical Member vs Member Design: batch mode vs design module

    Ok, so which method is preferred? I see the benefit for using the Steel Design and RC Designer for physical members comprised of multiple beam elements. What are the pros and cons of both?
  8. STR04

    Virtual Joist Girders (VJG) as Moment Resisting Joist Girder

    Has anyone used VJG's as a moment resisting joist girder in RISA 3D? What do you do with the DL moment if this is eliminated because the bottom chord is connected to the column after the DL is installed...well according to SJI there's no DL moment. How does RISA even perform a code check on...
  9. STR04

    Semi-Rigid Diaphragm for Metal Roof Deck

    Has anyone modeled a semi-rigid metal deck diaphragm in RISA-3D? I would like to find some guidance on adjusting my steel plate thickness and shear modulus (G) to account for proper deck stiffness with fasteners. I asked RISA support and they did not have any specific quidance on this topic...
  10. STR04

    Natatorium Roof: Stainless TEK Connector - 410 versus 316

    I'm no metallurgist, but my take from this old thread is that the 316 is far superior from the 410 for corrosion resistance. http://www.eng-tips.com/viewthread.cfm?qid=330465 I guess the advantage of the 410 is its hardness when tapping into metal so I can see its advantage over 316. I'm...
  11. STR04

    Yellow Poplar from late 1800's - Wood Properties

    Has anyone ever designed with yellow poplar that dates from the late 1800's? I can start with the values from the NDS, but wonder what I might expect from old forest growth if I had the material tested. TIA.
  12. STR04

    Tie Beams per Florida Building Code - Section 2121

    In accordance with FBC Chapter 21‚ Section 2121 there is no allowance for masonry tie beam construction ("U"-block) for commercial construction. How is this handled if the architect wants to use split face cmu and doesn't like to see a concrete banding (conc. tie beam) around his perimeter? TIA
  13. STR04

    Soil Structure Interaction (SSI) Using SAP 2000

    Has anyone performed an SSI using SAP 2000 or any other software for that matter?
  14. STR04

    Evaluating Older Masonry Walls

    I'm currently reviewing a load bearing masonry building in the state of Florida which was constructed in the 70's. I was wondering what compressive strength I should use when analyzing this structure. Some codes tell you to reduce the compressive strength by half if special inspection was not...
  15. STR04

    Occupancy Category III per IBC 2006, Table 1604.5

    IBC states for occupancy category III that Covered structures whose primary occupancy is public assembly with a capacity greater than 300 persons. Base on what the commentary states, if you exceed 300 persons yet the building's primary occupancy is not governed by public assembly (say...
  16. STR04

    Response Modification (R) for Structural Aluminum

    I'm reviewing an aluminum bleacher design (low seismic area) and they are using R>3. Whoa! So I look at ASCE 7-05 and cannot find any reference to aluminum except for mechanical piping. I also looked at the aluminum design manual and it references ASCE 7. I want to say nonbuilding structures...
  17. STR04

    Fabricator Designed Steel Connections

    I have a conflict with a senior engineer in our office who states that all connections are designed by the fabricator. I cannot say that he's dead wrong but I look at Section 3 of the 2005 AISC Code of Standard Practice for Steel Buildings and Bridges and it really implies that this...
  18. STR04

    ACI 318 Appendix D per 06 IBC 1912.1

    The 2006 IBC, section 1912.1 states ‘The strength design of anchors that are not within the scope of Appendix D of ACI 318, and as amended above, shall be in accordance with an approved procedure.’ First question: What defines an approved procedure? Is AISC's Design Guide 7 for Industrial...
  19. STR04

    Firewall Design

    What kind of lateral loads (wind, seismic) does a rated wall (now cantilever)see after the structure around it has burned down? What if the wall is 25' tall? TIA
  20. STR04

    Existing Wood Trusses

    I'm working on a re-roofing project in FL with 30 yr old parallel chord trusses. The roof is flat and has been leaking for years. I viewed some of the trusses exposed to moisture but could not see any real damage to the wood or plates. I doubt I can find the original truss mfr. so how would I...

Part and Inventory Search