It just came to my attention that there is now available on the market a double walled HDPE pipe with a water tight bell and spigot joint, large diameters for sewage applications.
Anyone have experience with it that they would like to share?
I want to put hard wired emergency generators at wastewater several wastewater pump stations.
The problem is that the industrial grade generators are too big.
For example,
a seven lot subdivision, pump station has two 5 hp pumps and they never both run at the same time. The actual KW that I need...
I'm going to ask this question a couple ways.
In a wastewater pump station, how long should a standby or spare pump be allowed to stand without operating?
Or, at what interval should should the lead-lag pumps be switched?
We have a 24 inch diam force main on a waste water pump station.
The length of the pressure line is 5,800 lf. In profile the line has two low points before discharge to a chamber. Gravity flow takes over.
From the point of discharge to the most distant low point is 2,200 lf.
There is evidence...
We are planning a water project in an urban setting. We will be taking a section of a large water main out of service. The temporary water service will result in the direction of flow in some streets being reversed. What are the risks? How can this be assessed in advance? What can be done to...
I read a 2007 post on this subject. Following up.
For now, I'm going to define a tapping sleeve as the stainless steel device and a tapping tee as a DI device with MJ gland to make the seal around the pipe.
My water crew insists that the DI tapping tees are the only thing they want used. Their...
What do you think?
We are going to install a low-voltage mixer (48 VDC) in a 2 MG water standpipe, 60 ft diameter 110 feet high.
I can either loop the power cable all the way up to the roof of the tank and down, or I can drill through the 1 3/8 inch thick plate and intall a water tight fitting...
It has come to my attention that some newer valve actuators are made of fiber reinforced polyester or other plastics.
I'm looking at hydraulic cylinder linear actuators in particular.
Any comments on how they perform and hold up?
We are replacing a 12 inch water main in a city street with cement lined ductile iron pipe. We will be stopping about 30 feet away from a highway overpass where the main is hung below the bridge.
The plan calls for finding the existing main, cutting it and coupling to it with a solid sleeve...
Should an above ground temporary water main be considered a potential source of contamination?
Should it be isolated from the permanent system with backflow preventers?
What if it is looped into the permanent system at two points?
The loop configuration makes the system more robust and...
I ran the following post a few years ago. Since 2005, does anyone have any further comment?
Question: Has anyone had experience using wire-type heating elements directly inserted into water supply piping to prevent freezing? Anyone experienced adverse effects on the quality of the water...
We have recently moved into a new building. A gentleman in the office has asked if new toilets in public buildings have a minimum clearance from the seat to the level of standing water in the bowl? (This is a serious question and I only wish it was mine.)
I work for an old New England town. Lots of ledge, elevation change and dense overgrowth.
We want to eliminate some dead ends in the water distribution system. If I have two 8-inch dead ends about 400 feet apart, tough field conditions. There is plenty of fire flow at both ends.
Instead of...
It's been a while since the last thread on this subject. I'm interested in the latest thoughts from water distribution operators or designers. Is there any reason we should not allow HDPE tubing for water services? We are in the northeast US. What about the service from the main to the curb stop?
I'm replacing about a mile of unlined 6-inch cast iron pipe in a busy suburban street. The line has about 100 services. In the same street there is a newer 16-inch CLDI distribution main in parallel, with several cross connections. I can either remove and replace the old line and reconnect...
Has anyone had experience using heating elements directly inserted into water supply piping to prevent freezing? Anyone experienced adverse effects on the quality of the water?
There is a product furnished by Tyco Thermo Controls that is similar to heater tape but is inserted into the pipe...
Has anyone had experience using heating elements directly inserted into water supply piping to prevent freezing? Anyone experienced adverse effects on the quality of the water?
There is a product furnished by Tyco Thermo Controls that is similar to heater tape but is inserted into the pipe...
This has to be a common problem.
In one street in my town there are two water mains.
A house could have been connected to either of the mains.
From the records, it is not possible to know for certain which line a given customer is connected to.
Does anyone have any cheap tricks?
What about...