  1. Boghi1990

    Thermal Bowing Insulated Steam Line

    Hi, The client has asked for a thermal bowing analysis for a thin walled insulated steam line. The client wants to investigate if thermal bowing occurs and if it is occurs what stress are developed in the pipe when the line is warmed up during the winter time, when the ambient temperatures can...
  2. Boghi1990

    Output Results Stresses

    Hi, I have run a structural analysis to investigate the Circumferential, Radial & Axial Stresses in a pipe wall. In the stresses output results, there are listed several types of stresses(Von Mises Stresss, Principal Stresses and Tensor Stresses). Which of these do I need to look for in order...
  3. Boghi1990

    Output Results Stresses

    Hi, I have run a structural analysis to investigate the Circumferential, Radial & Axial Stresses in a pipe wall. In the stresses output results, there are listed several types of stresses(Von Mises Stresss, Principal Stresses and Tensor Stresses). Which of these do I need to look for in order...
  4. Boghi1990

    Circumferential, Radial & Axial Stresses , Output Results Algor Autodesk Mechanical Simulation

    Hi, I have run a structural analysis to investigate the Circumferential, Radial & Axial Stresses in a pipe wall. In the stresses output results, there are listed several types of stresses(Von Mises Stresss, Principal Stresses and Tensor Stresses). Which of these do I need to look for in order...
  5. Boghi1990

    Thermal Stress Model Constraints

    Insulated main steam lines running from boiler stop valves to turbine main stop valves. The lines are 18 inches and 12 inches with 8 inch and 7.5 inch insulation thickness. The ambient temperature where this steam lines are installed is about 70F. Steam lines are warmed up during thecold start...
  6. Boghi1990

    Thermal Stress Analysis Model Constraints

    Insulated main steam lines running from boiler stop valves to turbine main stop valves. The lines are 18 inches and 12 inches with 8 inch and 7.5 inch insulation thickness. The ambient temperature where this steam lines are installed is about 70F. Steam lines are warmed up during thecold start...
  7. Boghi1990

    Thermal Stress Analysis Constraints

    Insulated main steam lines running from boiler stop valves to turbine main stop valves. The lines are 18 inches and 12 inches with 8 inch and 7.5 inch insulation thickness. The ambient temperature where this steam lines are installed is about 70F. Steam lines are warmed up during thecold start...
  8. Boghi1990

    Main Steam Lines Thermal Stress Analysis

    I have to determine the thermal stresses in the wall of pipe, during the start up/warm up of 18 inches and 12 inches with 8 inch and 7.5 inch insulation thickness steam lines. The length of the lines is about 190 feet and consists of a few bends, two Wye Tee fittings, pipe and insulation. These...
  9. Boghi1990

    Main Steam Lines Thermal Stress Analysis

    I have to determine the thermal stresses in the wall of pipe, during the start up/warm up of 18 inches and 12 inches with 8 inch and 7.5 inch insulation thickness steam lines. The length of the lines is about 190 feet and consists of a few bends, two Wye Tee fittings, pipe and insulation. These...
  10. Boghi1990

    Centrifugal Pump Nozzle Loads Verification

    Hi, Are centrifugal pump nozzle loads solved for the operating temperature or are they solved for the design temperature? In my piping stress model I have defined the design parameters as T1 & P1, and the operatin parameters as T2 & P2. The pump is a centrifugal In-Line Vertical pump. Any...
  11. Boghi1990

    Piping Loads on a Surface Condenser

    Hi, I have run a pipe stress analysis for a piping system which carries condensate to a condenser. Two of the lines (NPS 4 & NPS 6) are piped to a surface condenser. The lines run through the condenser shell(3/4" thickness). They are welded on both sides of the surface condenser and run a few...
  12. Boghi1990

    Piping Loads on a Surface Condenser

    Hi, I have run a pipe stress analysis for a piping system which carries condensate to a condenser. Two of the lines (NPS 4 & NPS 6) are piped to a surface condenser. The lines run through the condenser shell(3/4" thickness). They are welded on both sides of the surface condenser and run a few...
  13. Boghi1990

    Design Velocity for Drain Steam Lines

    Boghi1990 (Mechanical) 9 Dec 11 1:30 Hi davefitz, I have several drain lines piped to a flash vessel. The drains are collected into 4 manifolds. Superheated steam flows through these drains. Sonic velocity(choking) occurs at the end of the drains. I am trying now to size the manifolds. I was...
  14. Boghi1990

    Sizing Flash Tank (Coal Power Plant)

    Hi, I am trying to size a flash tank. There are 19 drain lines (sizes varying from 3/4" to 10") coming into the flash tank. From the flash tank there are a 3" line and a 6" line running to a condenser(pressure in the condenser is 1.5Hg inch, vacuum). Is anybody out there who knows what...
  15. Boghi1990

    Piping Design Centrifugal Pump

    Hi, Why the suction and discharge lines have to be one or two sizes larger than the pump connection nozzles? What could happen if the suction or discharge lines are larger than the pump suction or pump discharge nozzles? I would appreciate if anyone can help me with an answer to this topic...
  16. Boghi1990

    Piping Design Centrifugal Pump

    Hi, Why the suction and discharge lines have to be one or two sizes larger than the pump connection nozzles? What could happen if the suction or discharge lines are larger than the pump suction or pump discharge nozzles? I would appreciate if anyone can help me with an answer to this topic...
  17. Boghi1990

    Piping Design Centrifugal Pump Piping

    Hi, I do not have too much experience in piping design.I would appreciate if there is anyone out there who could give some advice on the following questions. Regards, One Point "When the centrifugal pump is supported by piping, pipe supports should be installed on both sides of the pump as...
  18. Boghi1990

    Transient Thermal Storage Tank Model

    Hi, A 24 feet dia, and 40 feet cone shaped roof uninsulated storage tank, filled with 80% crude oil. The fluid in the tank is stationary and the tank is exposed to ambient air. The intial mean temperature of the crude oil in the tank is 20C.The data available is the daily min. and max...
  19. Boghi1990

    Mesh Size CAD geometry and Manual Meshing

    Hi GBor(Mechanical), Is there any basic guideline which can give an idea on what would be the appropiate mesh size when one starts meshing a CAD model imported into Algor? The same question if the mesh is created manually in Algor FEA editor ? Is the mesh size dependent of the actual...
  20. Boghi1990

    Algor Procedures & Guidelines

    Hello, I am seeking for some material/documentation which can help me to set up a list of procedures and guidelines for Algor modeling and analysis. Looking forward to getting some tips and advices. Kind Regards, One Point