  1. edemarcos

    Nozzle design for FRP tanks

    For steel vessel we refer to WRC107, but there is nothing for FRP tanks. I need to define allowable loads ( forces and moment ) acting on a nozzle. I will appreciate any suggestion and help. Manu thanks in advance.
  2. edemarcos

    Anyone knows french code CODETTI ?

    Please, I need some information about this code. I shall appreciate every information, note or link about this code and where I may found it. Many thanks in advance
  3. edemarcos

    ASCE 7-02 WIND ON PIPING

    I wish to know how to calculate wind gust factor for piping. All data in ASCE are for buildings, but not for piping. Many thank for any informations.
  4. edemarcos

    Metric bolts for ANSI flanges

    Problem : Use metric bolt on ANSI flanges. There are reference codes or rules to have the exact change ? Many thanks in advance.
  5. edemarcos

    Distance of bolt to OD on reverse flange

    I need to check a reverse flange with stud-bolts. OD flange 813 mm Stud Bolts M39 OD 39 mm Bolt circumference diameter 749.3 mm Distance from the OD to bolt 12.35 mm I does not found any code ( ASME, BS, Eurocode ) that give me a rule to define the minimum distance between the bolt and the...
  6. edemarcos

    Problem : Tank lifting as per appendix J

    I refer to Par. J.3.8.3 of API650 The required safety factor of 4 is referred to Tensile strength or Yield Strength of material. Why I must double the load acting on a lug ? If a customer require 1.5 or 1.25 I may assume this value or I must assume 2 ? Many thanks in advance
  7. edemarcos

    Piping Stress analysis & Flanged Joints

    Often, when I perform a stress analysis of pipe system ( B31.1 or B31.3 ) I have that at the flanged joints I have a lower than allowable stress. If I calculate the equivalent pressure Pe at the flanged joint location I have the ( Pd+Pe )> Prating. Due to the fact the ASME B31.1 and 3 do not...
  8. edemarcos

    Tank Lifting ( appendix J )

    I refer to Par. J.3.8.3 of API650 The required safety factor of 4 is referred to Tensile strength or Yield Strength of material. Why I must double the load acting on a lug ? If a customer require 1.5 or 1.25 I may assume this value or I must assume 2 ? Many thanks in advance
  9. edemarcos

    Flange calculation as per ASME VIII div.1

    My problem is if I must consider the flange thk corroded or not. Many thanks for Your help
  10. edemarcos

    Equivalent pressure for bolted joint

    Please, I need to know how to calculate the equivalent pressure acting on bolted joint due to an external bending moment and axial load. Many thanks in advance.