Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: seattlemike
  • Content: Threads
  • Order by date
  1. seattlemike

    SMRF with HSS?

    Has anyone seen an approval for a HSS Moment Frame connections as a SMRF? I have seen the standard RBS, WUF-W, WUF-B, etc, etc (although they are not all approved), but I have not seen any discussion of HSS as Special Moment Resisting Frames. Any input? Thank you, SeattleMike
  2. seattlemike

    Why does standard Welded Wire Mesh does not meet ACI criteria?

    Hello fellow Structural Engineers, This may be a dumb point, but 6x6 - W1.4xW1.4 WWM comes up woely short of the ACI requirement of 0.0018.... in a 4" slab, WWM = 0.28 sq in/ft, but ACI requires 0.0018*4*12 = 0.0864 sq in/ft. what's that all about? Why does standard Welded Wire Mesh that we...
  3. seattlemike

    Bar Splices in CMU for IBC are too much?

    Hello fellow structural engineers, Several years ago, I think I went to seminar on the UBC transition to IBC, and it mentioned this problem with Masonry, and I am just now running into it: IN the WSD design method: IBC has an equation for lap splices that overrides ACI 530, and for #5 bars...
  4. seattlemike

    Aluminum pole in Concrete?

    Do standard Aluminum structural shapes/alloys have a problem (chemical) with being embedded in concrete? Thank you, SeattleMike
  5. seattlemike

    lawsuits over Seismic or Hurricane damage (rewrite)

    Hello fellow Structural Engineers, I am a licenced and practicing structural engineer in Washington, and I am doing research into lawsuits that have been brought against us for damage due to earthquakes or hurricanes. However, I am having trouble finding any cases where this has happened...
  6. seattlemike

    window failures: enclosed v. partial enclosed?

    Windows are typically designed for a failure rate of 8 or 9 in 1000, that is less than 1%. However, in modern buildings that are complete curtain walls, each side might have several thousand 2x4 windows in the curtain wall... and typically a few fail... so, that would make one think that ANY...
  7. seattlemike

    Florida Building Code: Partially Enclosed v. Enclosed

    Hello Structural Engineers, Question on the Florida Building Code, in the Wind-Debris Zone (but NOT the High-Velocity Hurricane Zone): Our firm is designing a 7-story office space-parking building in downtown Cape Coral, Florida. Still waiting to hear if it's exposure B or C. The architect...
  8. seattlemike

    What is HVHZ in Florida 2006 code?

    What is the definition on the High-Velocity Hurricane Zone in the Florida 2006 building code? Over 130 mph? 110 mph? Thanks, Seattle Mike
  9. seattlemike

    Field Gluing 1/4 plywood together? Curved? Bad Idea?

    Hello fellow Structural Engineers, I have a house project in which the contractor missed building a major shear wall (1/2" plywood x 12" long x 3 stories high.) So, one idea we have is to sheath the curved (in plan) wall that is the curved stair outside wall. It is the only full height...
  10. seattlemike

    Steel Roof Deck as a sub-diaphragm

    Hello Engineers, So, while steel roof deck is not allowed to count as continuous ties for sub-diapragms across the length of the building, it is my understanding that metal deck is typically considered adequate for tension and compression bracing/anchorage of the sub-diaphragm whereas on a wood...
  11. seattlemike

    3D foundation & stem wall analysis computer program?

    HELP!!! haha, sorry, I couldn't resist. Hello my good Structural Engineers, Happy Holidays to you all. I have a question that has bothered me for some time: Typically house foundations have perpendicular walls that help with overturning, even Z shaped walls, and they have point loads...
  12. seattlemike

    How to account for curve in radial steel stair design?

    Hello, QUESTION: I am attempting to design a curved steel staircase, but I am unsure of how to calculate the effect of the curve. GIVEN: The inside radius is 15'-9" and the outside radius is 19'-7". The stair stringers span approximate 16.5'. The strair treads are 14 GA steel and 11" long...
  13. seattlemike

    Base Isolation costs

    Hello fellow Structural Engineers, Has anyone done research on the costs of Base Isolation of buildings? With the savings of reducing base shears by a factor of 3x or 10x, or the idea of keeping the remainder of the building elastic, I was wondering if there could be an overall savings in...
  14. seattlemike

    SLENDER Concrete Shear Wall analysis

    SLENDER Concrete Shear Wall analysis Hi All, So, typically, I've seen engineers run ETABS linear(elastic) dynamic analysis of Concrete Shear Walls, with ACI effective stiffnesses for cracked and uncracked sections. On smaller buildings, I've seen engineers just run RISA wall panels elements...
  15. seattlemike

    SLENDER Concrete Shear Wall analysis

    Hi All, So, typically, I've seen engineers run ETABS linear(elastic) dynamic analysis of Concrete Shear Walls, with ACI effective stiffnesses for cracked and uncracked sections. On smaller buildings, I've seen engineers just run RISA wall panels elements, discretized to get tensile forces for...
  16. seattlemike

    1/3 increase for seismic/wind for masonry?

    There has been some talk that the 1/3 increase for masonry is going away in the IBC 2006. But it's still in the IBC 2003, right? 2.1.2.3 of the ACI 530-02/ASCE 5-02 seems to allow the 1/3 stress increase, which can be used with the ALTERNATIVE basic load combinations of the IBC 2003. What do...
  17. seattlemike

    PT Slab live load reduction?

    Banded tendons in PT slab design are meant to support a wide area, so it seems live load reduction per IBC could be acceptable? Is that correct? What do you think?
  18. seattlemike

    PT slab: exposed v. protected?

    Hello fellow engineers, My office is reviewing a PT slab for another engineering office. The project is townhomes and a courtyard over a PT deck with parking below. The other engineering office is only using 3/4" cover instread of 1" (for weather exposure). I assume they are going to justify...
  19. seattlemike

    PT slab: effective width?

    Hello fellow engineers, I have not designed a post-tensioned slab before although I do have several design examples and some office help. For Post-Tensioned concrete slabs with banded tendons, what is the effective width for the slab design? My slab is 10' thick, and the trib load is 20'...
  20. seattlemike

    1% Minimum in Concrete Columns? What is the theory?

    Hello fellow engineers, Question 1 of 2: Our ACI code specifies a minimum 1% steel in columns so that we don't have catastrophic failures such as in the Pakistan earthquake last year. I believe the minimum 1% is in there to provide 3 fold protection: 1) Ductility in the ends and joints...

Part and Inventory Search