Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: gr2vessels
  • Content: Threads
  • Order by date
  1. gr2vessels

    Pressure vessels registration in Argentina

    I am unable to find any reference to the pressure vessel registration in Argentina, can anyone help?
  2. gr2vessels

    Range of sizing ratio for cold expansion

    Can anyone please explain the following: API 5L allows a range of sizing ratio for cold-expanded pipe 0.3 - 1.5%. However, many specifications and manufacturers narrow the range to 0.8 - 1.5% (no heat treatment). What is the reason to use lower limit 0.8 against of API 5L allowed 0.3%? Cheers...
  3. gr2vessels

    Flange rating for 316/316L dual certification

    I was unable to find this topic clarified in previous posts. Which table should we use for a dual certified 316/316L flange? Table 2-2.2 or Table 2-2.3 of ASME B16.5?
  4. gr2vessels

    Venting interstitial space UL 142

    Can the interstitial space in a self bunded dilute ethanol storage tank be vacuumed as means of controlling the inner shell integrity? The storage tank is not exposed to any external pool fire or any excessive heat. The vacuum is monitored by a vacuum switch to alert loss of containment. A vent...
  5. gr2vessels

    GTAW - TWIN

    Suggest ask your vendor;- he might charge tuition fees. Cheers, gr2vessels
  6. gr2vessels

    Air starting fire pump diesel engine

    I am trying to locate a high pressure air compressor driven by the fire pump engine (approx. 2500 psi), able to compress the air in several G-cylinders, to be used for air start of this NFPA 20 diesel engine (100 kW) fire pump. I imagine the delivery volume shouldn't be high, to minimize the...
  7. gr2vessels

    ConAgra Explosion - Purging gas pipes

    Code changes! Refer link below: http://www.hazardexonthenet.net/article.aspx?AreaID=2&ArticleID=31288 Finally, the common sense prevails?! Cheers, gr2vessels
  8. gr2vessels

    Work Safety Awards 2008

    Yeah, right. Cheers, gr2vessels
  9. gr2vessels

    Allowable stress in AS 1210

    What is the allowable stress in AS 1210 for SA 266 gr 4? Please advise... Cheers, gr2vessels
  10. gr2vessels

    Even Japanese pipe suppliers...

    Would you believe it? read below... http://www.japancorp.net/article.asp?Art_ID=18398 gr2vessels
  11. gr2vessels

    West Texas Refinery

    Does anyone have details of the cause of explosion on Feb 19, or any source of information? Cheers, gr2vessels
  12. gr2vessels

    What level of materials certification

    The "pressure equipment" requisitioning engineer would normally specify the required materials certification to the level 3.1B or C per ISO 10474, depending on the hazard level and other conditions. However, it seems that the structural engineers tend to be a lot more lenient towards the...
  13. gr2vessels

    AS 1210 Revision 2007

    Dear all, Would anyone have information on the expected revision of the AS 1210, due on 15 Dec 2007. Is it still on, any info on the extent of revision? Perhaps, someone from the board might give us an idea? Cheers, gr2vessels
  14. gr2vessels

    B16.47 Flanges T - P ratings confusion

    Gents, Here we go again. Pls note that ASME VIII (2007 Edition) in Clause U-3 states that the "acceptable editions" of standards are nominated in Table U-3, and this Table references the superseded 1996 Edition of ASME B16.47 (large diameter steel flanges)and not the current 2006 version...
  15. gr2vessels

    API 660 8 th Ed. is out

    I 've got my copy of API 660 Shell and Tube Exchangers, August 2007 edition. It went quite unnoticed until now, lack of interest? gr2vessels
  16. gr2vessels

    Freeboard calculation for height of sloshing wave

    Gents, Would be kind someone to advise if the sloshing wave height is to be considered in the design of external floating roof tanks, perticularly for the design of freeboard height? Thanks anticipated, gr2vessels
  17. gr2vessels

    Crack of reo pad fillet weld

    Hi all, The Duplex pressure vessel on this FPSO has developed a small crack (3/4" long) on the reo pad's fillet weld (12" NPS inlet nozzle), since last inspected 12 months ago. Salt ladden environment and warm H/C condensate + salty water inside, 400 psig pressure. Is there any maximum size for...
  18. gr2vessels

    Stud Welding limitations

    Gents, I did the necessary reseach for the limitations on the use of stud weld - Duplex S/S studs 5 mm dia on 2.5 mm Duplex plate, without success. The welding tests show that there is high ferrite content and high hardness developed at the edge of the weld, including the HAZ, which is pointing...
  19. gr2vessels

    Spiral Plate H/E failure

    G'day to all, Back in Nov. '03, the topic of spiral exchangers failure was debated and the consensus was that Alfa Laval didn't seem to have the fabrication under control, hence the H/E were prone to failure under certain circumstances. I'm in process of evaluating a new SPHE design by Alfa...
  20. gr2vessels

    Manufacturer's Design Report / WPS-PQR's

    G'day gents, Could someone please advise if the WPS / PQR's are included in the list of documents under the review of PE (Manufacturer's Design Report), for a vessel designed to Div. 2? Regards, gr2vessels

Part and Inventory Search