  1. benjaman

    AS3600_Circular pile shear capacity

    Hi, Has anyone done any circular piles shear capacity check using AS3600? Can anyone please shed any light?
  2. benjaman

    PT Slab Property Modifier

    What Slab property modifier do you guys use for PT slab modelling in ETABS, note model will be for lateral analysis, not slab design. Thanks
  3. benjaman

    Etabs_Interpretation of diaphragm forces

    Hi, Can anyone please explain how to interpret the results obtained from display/diaphragm forces? I am getting a mixture of positive and negative forces at different nodes of the same floor for wind load applied in 'Y' direction, which doesn't make much sense to me. Will appreciate if...
  4. benjaman

    Sequential Analysis with Etabs 2016 16.2.0

    Has anyone done a sequential analysis with ETABS 2016 16.2.0 ? It lakes a lot longer and eventually crashes. This model used to work fine with earlier versions of ETABS 2016. Thanks
  5. benjaman

    Slab to Jumpformed wall connection using centrally located inserts

    thread507-319174 Hi, This thread is a continuation to the thread above. I have designed the slabs as simply supported and want to connect them to jumpformed wall using central inserts. Do I need to use equivalent number of centrally placed inserts to match my bottom bars? What do I need to...
  6. benjaman

    Modelling Precast Shear Walls in Etabs

    thread802-349319 On the Thread above regarding modelling precast shear walls in ETABS It reads: "1. Model the wall with shell elements roughly. In order to simulate with detail the joints, you can modify the property modifiers of the elements close to the joint only. 2. Then, after the...
  7. benjaman

    ETABS 2013 _AS1170.4 Response Spectrum

    Anyone using AS1170.4 response spectrum in ETABS 2013? Results I am getting is not convincing, about twice that of static calc.please coment.
  8. benjaman

    ETABS Shell Stresses_ Difference between top/bottom/maximum stress

    Hi, When looking at wall stress plots for direct stress do you guys look at top/bottom stresses or maximum stresses for reinforcement design? Can anyone shed any light on their differences? Thanks
  9. benjaman

    ETABS Walking Colum

    Has anyone tried to obtain floor diaphragm forces resulting from walking columns from ETABS?
  10. benjaman

    Design of stair supported on walls

    Hi, I am designing a stair supported by RCC walls on both sides. Now, in a few articles I saw that connecting stairs to walls on both sides is not a good practice in case of seismic design. Any comments regarding this will be appreciated. Thanks.
  11. benjaman

    Garge load on floor slab

    Hi, We are designing a 6 storey residential building with its basement and ground floor to be used as garage/ parking area. Can anybody please provide me with some guidelines regarding how to apply the imposed/live loads due to vehicles on the slabs. Thanks in advance.
  12. benjaman

    Equipment damage during SPT

    Hi, we are doing Standard penetration Test for a depth of 35. The rope controlling the hammer gave away after reaching a depth of 22m. My question is can we still continue with the same bore hole for the remaining depth after the equipment is repaired?
  13. benjaman

    Slab Top Reinforcement

    Hi, I came across the design of a slab with edge beams which has nominal negative moment near support and the continuous positive reinforcement which is continuous through this region is theoretically adequate to cope with that moment. My question is, in that case do we need to provide any top...
  14. benjaman

    Design of irregular shaped columns

    Hi, Could anyone please shed some light on the design reinforced concrete irregular shaped column design, e.g. hexagonal, L-shaped ?
  15. benjaman

    Curved column

    Hi, has anyone designed a curved column here? In my new building project I need to design some curved columns of 700*300 mm² dimension. The column length is 12.6m . They support only a cantilevered part of the roof and are curved along their height. I also wonder if some sort of bracing is...
  16. benjaman

    Flat slab analysis

    Hi, For flat slabs is a 2D frame analysis or a finite element model more appropriate for analysis? I mean which would most engineers go for. Any discussion/suggestion regarding how to model flat slabs along with a combination of columns and load bearing walls would be greatly appreciated...
  17. benjaman

    Pile cap modelling

    Hi, I am trying to model a 4-storied concrete building on piles with STAAD Pro. I have modelled the slabs as palte elements. I have grade beams in my ground floor. Can anyone please suggest what is the best way to model the pile cap in this situatuation. Assume, there is going to be 4 piles...
  18. benjaman

    Modelling an elastomeric bearing

    In STAAD I modelled elastomeric bearings as vertically oriented beams with one end fixed and the other pinned. This pin support is actually on the node conncting the girder to the bearing. But I get 0 dispacement at those pin supported nodes when applying a transverse load. Why is this happening?
  19. benjaman

    LRFD seismic load calculation

    I am designing a 961 long flyover. It consists of 31 spans. The girders are considered to be simply supported.Elastomeric bearings are used between girders and pier cap. The foundation consists of 9 piles.For seismic load calculation I am using single mode spectral analysis method for seismic...