Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: apatjr
  • Content: Threads
  • Order by date
  1. apatjr

    ASME PPC-1 traning

    We were asked to develop a torquing procedure to follow PPC-1. But now our customer asking to submit a traning certificate. We're basically bolting about 40, 2", 3" and 4" flanges. Does ASME PPC-1 require a certificate?
  2. apatjr

    Relief Valve Sizing for Vessels Containing Solids

    The thermal expansion calculations for pressure vessels are based on an empty vessel. If the empty vessel is in a fire and the gas stored starts to expand rapidly the relief valve will protect the vessel from damage. However, what if the vessel is filled with a solid like desiccant in a...
  3. apatjr

    D1.3 & Macrophotograph Requirement

    We are using a GMAW procedure to seal weld a container's sheet metal wall. We had to submit our procedure for review. We've been asked to submit a copy of the macrophotograph of the weld used in qualifying the procedure. Unfortunately, we did not get it done as we were only using the procedure...
  4. apatjr

    Starting Compressors at Low Ambients

    We're working on a project where some 225kW rotary compressors are operating outside. The ambient temperature will vary from 21 to 93 degrees F throughout the year. When operating the compressors will be operating at approx. 205 degrees F. The units have freeze protection and will not be...
  5. apatjr

    Copper faced earth lug

    We have to weld grounding lugs on our package skids. Usually we weld a small stainless steel pad in the corners for the customer to ground to. We have been asked to supply a copper faced ground. We would rather not go to a plating company as we have such a small quantity of pieces. Does anyone...
  6. apatjr

    ATEX approved small PLC

    We're trying to design a small control panel for use in an ATEX Zone 1 area. So far we've found all the end devices that are suitable for this area. We usually use an Allen-Bradley Micrologix 1500 in the US as we only have 5 inputs/7 outputs and 2 anlaog inputs through an expansion module...
  7. apatjr

    Allowable Nozzle Load Location

    We are being asked to supply the allowable nozzle load at a vessel contained inside a package skid. This nozzle connection is supported within 5 feet as the piping changes direction. We've supplied the allowable nozzle loads at skid edge connnections, which is where the customer will hook-up...
  8. apatjr

    Looking for Hazardous Area Hourmeter

    Has anyone had any luck finding an hourmeter that can be used in a Class 1, Div 2 Area and has the certificate to back it up. Thanks in advance.
  9. apatjr

    Air Filter Certification

    We are working on a project supplying air compressors to a European company. One of their engineers is asking for a certificate of conformance for the inlet air filter. I've gone to the filter manufacturer and do not know what I am requesting. Does anyone have any idea what this form looks like...
  10. apatjr

    High Temperature HMI

    Has anyone had any luck in finding a HMI that can operate in a 60ºC enviroment and is rated for a Class 1 Div 2 area. Cooling through a vortex cooler is not possible as there is no excess air. Thanks in Advance
  11. apatjr

    ISO 5011 COC

    We are being asked to supply a Certificate of Conformance on an inlet air filter for an air compressor. The filter supplier has test conforming to SAE J726, but not to the new ISO 5011 standard. What does this certificate look like, so I can instruct the filter supplier.
  12. apatjr

    API RP14C C&E Diagrams

    I'd like to know if there is a guide explaining how the C&E diagrams are to be created. On simple cause effect systems it looks straight forward. However, in systems where one cause can have multiple effects which in turn can have secondary effects it becomes more difficult. Any help would be...
  13. apatjr

    Protecting Shell & Tube Exchanger from a Ruptured Tube

    Need assistance in calculating how to size a relief valve on the water size of a sheel & tube heat exchanger for a sudden rupture of one of the pressurized tubes on a 3-stage compressor cooling system. The internal pressure is 3000psig and the closed loop water pressure is 70 psig. A water...
  14. apatjr

    Is Rust & Oxygen Rich Air a Hazard

    We're working on a process where nitrogen is extracted from compressed instrument quality air by removing O2 from the air. This extracted oxygen along with regular air is vented to atmosphere through a carbon steel pipe at near atmospheric pressure. This process increases the precentage of...
  15. apatjr

    GUA is it a fitting or enclosure?

    We are supporting conduit going to a 1/2" GUA fitting on one end and hanging a solenoid off the other end. The support is within inches of the GUA fitting. Our inspector is saying that the GUA fitting must be supported at two points to comply with NEC 314.23(E). I like to ask whether a GUA...
  16. apatjr

    Recommended software for medium sized skid

    I work for a company that design and fabricate skids for compressed air systems. These packages range in size and complexity dependent on the number of compressors/dryers and associated equipment requested. Due to the amount of piping our packages have the main skids are designed to minimize...
  17. apatjr

    Equivalence to a High Frequency Start

    In welding statinless with a GTAW procedure. Would a lift start be considered an equivalent to a high frequency start. Thanks in Advance

Part and Inventory Search