I have a PLC-5/80E/E that has a steady force LED illuminated. There are NO comms either from the DH+ or the RS232 ports. The Processor LED is steady red. I've tried leaving the power off with the battery disconnected overnight. However, the problem still exists.
I took the CPU board out and...
I have a GE Fanuc relay module IC660BR101B mounted in a terminal base with the part number IC660TBR101A. My customer says that the TBR part number should end with the same suffix as the BR part number in order for the module to work.
What is the A (or B) represent. Is it just a series...
I was given a T47 to test and on power up it says: Invalid configuration information - please run SETUP program. Is this the BIOS setup? It appears that the hard drive is bad, but I'm not sure yet.
Is there a way to get into the BIOS and look at the boot sequence. The floppy drive works. When...
I have an Allen Bradley IMC 4100-234 4-AXIS drive controller connected to a 1391BESAA22AQB SERVO asnd connected to a 1326AB motor. I'm using a pre-engineered cable AB 4100CCAQB cable for feedback and servo control. We're using GML software
Axis #0 and #1 check out fine when I do the...
Does anyone have any experience with the 1784 PKTS/A card? We're trying to establish comms with RSLinx but we cannot seem to load the correct driver. We've been in touch with AB but the drivers on the web site don't seem to work.
We're using Windows 2000 Pro. for the O/S.
Any help appreciated...
Need some help setting up a B883-201 RTD Module. I'm using ProWorx and a 984-780 Processor. Does anyone have the wiring diagram and the data entry and setup for the Data Watch Window?
The registers are input: 30010, 30011, 30012; and output 40010, 40011, 40012. The module appears to be a...
Does anyone have the wiring diagrams for the SPEC200 analog controllers model number KIT-E27-ID-SAS-TA? I need the terminal connection diagram.
thanks,
CTG
I could use some help configuring a N4V2 (4 inputs, 2 outputs) analog i/o block talking to a SLC. In the past I have used a 1747SN scanner module for discrete inputs with no problems.
However, with the analog block, I get good communications with the scanner and block but do not see any data in...
Anyone out there familiar with the Allen Bradley T30 industrial terminal?
I'd like to know how to clear the memory. The full model number is 1784-T30G.
Could also use some help locating a manual. I searched the web but came up empty.
thanks,
CTG
Is there anyone out there that could help me program STL or a function block so I can get a SIMATIC S5 115U 943 processor to output a value to the real world via a 470-LA12 analog output module?
I've been struggling with this for a while but hit a brick wall.
I really need someone to walk me...
Can anyone supply a document showing the dip-switch settings for the B875-101 analog input module? Modicon's web site does not seem to catty the info.
thanks,
CTG