  1. trilinga

    Design of V shaped RCC columns

    I am invoved in the design of an octogonal shaped RCC building. Is there a design procedure or a handbook to design V shaped RCC columns (with an included angle of 135 deg.)? Thanks for the help Trilinga
  2. trilinga

    DEFLECTIONS OF EQUIPMENT SUPPORTING ELEMENTS

    I have to support an equipment on a structural frame resting on a set of existing roof beams. The lateral deflection of the frame consists of two parts, viz. the lateral deflection of the frame and the additional lateral deflection due to the differential vertical deflections of the supporting...
  3. trilinga

    OPTION IN 'COUNTIF' COMMAND

    I am not familier with writing of Macros in EXCEL. I have an Excel spreadsheet in which I have data of different categories identified through different colour fills in the respective cells. If I have to count the number of cells with a specific category, is there any option in countif command...
  4. trilinga

    HOW FAR IS IT RIGHT?

    Recently, I and my colleague had an argument. I am designing a foundation for a framed structure. The soil is good with Safe bearing capacity of 30T/Sq.m. for 25 mm. settlement as per the soil investigation report. I have modelled the frame with fixed base and obtained the axial load and...
  5. trilinga

    CRYOGENIC CONCRETE

    Is the composition of Cryogenic concrete different from normal concrete? I tried to search in the web but I do not find any specific definition for it. Any information or website reference available? Thanks for the help. Trilinga
  6. trilinga

    CONCRETE SHEAR STRENGTH AS PER EUROCODE-2

    I was referring to the following clause in Eurocode-2 (EN 1992-1-1). The clause 6.4.4 (2) defines the punching shear strength of a concentrically loaded concrete column base as below: Vrd = Crdc*k*(100*p*fck)1/3*2d/a >= Vmin * 2d/a ie. Vrd = (Expression1) >=(Expression2) I interpret the...
  7. trilinga

    DIAPHRAGM WALLS

    Can anyone suggest some good websites/references having detailed information about design and construction of diaphragm walls? Thanks for the help trilinga
  8. trilinga

    Life Safety Requirement for Industrial buildings

    I am collecting information regarding the Life Safety requirement for Industrial plant buildings adopted in different countries. Any information regarding the relevant building codes and regulations used in different countries which specify the egress requirement for buildings will be helpful...
  9. trilinga

    I have submitted the following Thre

    Dear all I have submitted the following Thread in the RESEARCH ENGINEERS- STAAD PRODUCTS Forum under the title,'A Simple problem but puzzling', which I came across in STAAD analysis The problem is a little strange and defys logic. One of the forum members has confirmed that the anamoly is...
  10. trilinga

    A SIMPLE PROBLEM BUT PUZZLING

    I had a peculier observation in analysing a simple single bay single storyed symmetrical frame,with fixed supports and with a uniformly distributed load on the beam. A very simple problem to solve indeed. The moment at the column base shall be 50% of the moment at the top of the column. Since...