Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: threeS
  • Content: Threads
  • Order by date
  1. threeS

    New Zealand LNG/NG

    In New Zealand, are LNG/NG classified as Hazardous Substances? Is NG Class 2.1.1A? Is LNG Class 3.1A?
  2. threeS

    UK Statutory Instrument - Threshold Quantity of Hazardous Substances

    Hi, all, I am looking for the threshold quantity requirement of hazardous substances. Please see whether you have ideas on the following for UK requirements: 1. It appears that SI 1982/1357 "Notification of Installation Handling Hazardous Substances Regulations 1982" has not been posted on...
  3. threeS

    Air or Water-Cooled Air Compressor

    I am now selecting the Air Compressor for a new power station. The expected capacity of Air Compressor is around 7 bar and 50m3/min. The Air Compressor (two-stage) will be screw type with intercooler and aftercooler. We require the water-cooled Air Compressor but the Bidder counterproposed...
  4. threeS

    HRSG / Deaerator Design

    I found there are three different arrangement for the Deaerator in a Combined Cycle Power Plant: 1. Deaerating Condenser - Deaerating process is carried out inside Condenser. 2. Low Pressure Drum Deaerator - Deaerating process is carried out insde the LP drum. 3. Separate Deaerator -...
  5. threeS

    EP, Bagfilter, Gas Cooler

    Referring to the thread below, http://www.eng-tips.com/viewthread.cfm?SQID=81007&SPID=794&newpid=794&page=1 My project has new delevopment. We will focus on the following measures to reduce particulate emission from a coal fired power plant:- 1. Retrofit an additional cell upstream of EP...
  6. threeS

    Coal Fired Boiler - Gas Cooling between Air Heater and EP

    As our coal-fired boiler has operated for 20 years, the air heater efficiency drops, the gas temperature leaving the air heater has increased by around 15 degC. This deteriorates performace of Electrostatic Precipitator downstread of air heater. Two possible solutions:- 1. Restore air heater...
  7. threeS

    How to specify supplementary firing equipments for HRSG

    Hi, anybody can tell key points to specify the supplementary firing equipments for a HRSG. The HRSG can be a vertical or horizontal type. The supplementary firing is limited to duct firing. The location can be at HRSG inlet duct or between first and second tube blocks counting from the gas...
  8. threeS

    Questions on HRSG design

    Questions on triple pressure with reheat HRSG:- 1. The material of HRSG superheater and reheater are usually T22. If change to T91, the thickness of the tube can be reduced. I think this can help to reduce the cycle fatigue. Is it correct? 2. For vertical HRSG, all headers are outside the...

Part and Inventory Search