  1. balaji28

    Recovery from refinery waste

    Hi Is it possible to recovery of valuable oil from VDU bottom - vacuum residue portion without the coker or delayed coker unit ?
  2. balaji28

    Ash removal from shale oil ( heavy fuel oil + gasoline mixture)

    Hi I am looking for a suitable filter to treat 250 cu.m/hr of process media comprising of 85% heavy fuel oil and 15% gasoline. The intent is to reduce ash content from inlet of 1000 ppm to outlet of 50 ppm. I need to make a CAPEX and OPEX comparison for various filtration technologies...
  3. balaji28

    Ash removal from shale oil ( heavy fuel oil + gasoline mixture)

    Hi I am looking for a suitable filter to treat 250 cu.m/hr of process media comprising of 85% heavy fuel oil and 15% gasoline. The intent is to reduce ash content from inlet of 1000 ppm to outlet of 50 ppm. I need to make a CAPEX and OPEX comparison for various filtration technologies...
  4. balaji28

    DOL Motors operated with a VFD

    Hi I recently received a quote for a motor and states that the starting method is "Direct on line". I had requested a motor to be suitable for it to VFD driven. When I checked with the motor manufacturer, they conveyed that the same motor is suitable for VFD start as well. I was under the...
  5. balaji28

    Motor selection for a 480VAC ,60Hz Supply

    Hi I need to select a VFD driven motor for Mexico where the supply voltage is 480VAC, 60Hz for an equipment. The standard motors available in market (ABB,IE3 / Equivalent) are either 460VAC, 60Hz or 500VAC, 60Hz. Which one is recommended - 460VAC or 500vac Motor and why ? Regards Bala
  6. balaji28

    Difference between PN 10 DIN 2576 and DIN EN1092-1 Form E/F.

    Hi Can you please advise the difference between PN 10 DIN 2576 and DIN EN1092-1 Form E/F. Regards Balaji
  7. balaji28

    Foot mounted 660VAC,50Hz,37kW CT Motor operated with a VFD

    Hi Can I operate a 660VAC,50Hz, 37Kw foot mounted -CT motor with a VFD ? Are these any special motors in terms of their construction, protection etc ? Regards
  8. balaji28

    440VAC, 60Hz motor on a 415VAC,50Hz supply (VFD)

    Hi - I would be running a 440VAC,60Hz,45Kw motor on a 415VAC,50Hz supply with a VFD. The motor assembly would be driving a vertical spindle assembly via a flexible coupling and worm gear (suitable for both 60Hz & 50Hz. The worm gear adapts the vertical assembly speed to the motor speed. The...