Hi!
For a Multiphase Pumping (MPP) system handling oil, production water, and gas, what would be the most suitable API plan recommendation? Is Plan 11/61 sufficient, considering the fluid composition and potential polymerization? The plan is for the suction side of the pump, and the pump is of...
Hey everyone!
I am very grateful for the support I've found in this group. Again, I am here with an operational question.
The situation is, when I am helping in sizing a multiphase pump, manufacturer offers only one twin screw option for handling about 35,000 bepd, but this configuration is...
Hi!
Im starting a new project completely different to what i m used to do, It is a natural gas engine, turbocharged, 2300 HP, 16 V-cylinder. The associated compressor is a reciprocating type, two-stage, double acting, four cylinders per stage. So the motor fuel is natural gas and the purpose...
Hi there,
I'm strugling with the selection for a MPP pump for an onshore oil field(located in the rainforest), the plan is to pump a gas, liquid and oil mixture (about 60%GVF), as you can see i m a jr. engineer and i m having a lot of doubts. The physical-chemical production water test says...