  1. T

    photovoltaic dust accumulation

    Goodday, How can l use AI to measure dust accumulation on solar panels and automatically clean them?
  2. T

    Siphon

    l have a tank 2m ×2m×2m. So my volume is 8m3. l want to be able to to siphon the liquid at 16m3/h, using it as a purge line for my hotwell. l could have installed a pipe and a valve at a bottom of the tank, but the problem this will need a shutdown. My question is there any equation to calculate...
  3. T

    Estimating steam consumption on a steam distillation column/ deodorizer

    We use sparging steam fo agitation and stripping in a deodorizer column. Is there a way l can calculate steam consumption of the continuous deodorization column. We use superheated steam, we superheat saturated steam from boiler house using thermic fluid in a superheater. Attached is a schematic...
  4. T

    Pressure drop vs volumetric flowrate

    l saw this article on LinkedIn, and applying this theory to practical, didn't add up. The way we reduce flowrate to a vessel, either for a liquid or steam is by restricting flow, increasing pressure drop and resulting in a lower flowrate downstream of the valve. ln this case it seems, for liquid...
  5. T

    Pipe inlet design

    Goodday. l have a vessel heating edible oil using thermic fluid through a heating coil. The inlet of the thermal fluid the pipeline is looped, l was wondering whats the purpose of looping. See attachment!
  6. T

    mixing ratios in a batch process

    Goodday. What is the minimum mixing ratio in a batch process? Say l have a 10 000L of crude oil and l want to add 0.1% phosphoric to the oil. To what volume should l dilute my acid to get effective mixing in a batch mixer? l figured if l mix 10L of acid to 10 000L of oil is too much of a volume...
  7. T

    pump and motor

    Goodday, l have a pump rated 5 5KW/2900rpm and l plugged 3.7kw/ 2875rpm motor. Will this damage the motor or pump?
  8. T

    Flowrate in a valve

    Goodday. Does a valve reduce volumetric flowrate. l ask because we use valves to reduce flowrate, but according to valve software, only pressure drop will be realized, but flowrate will not be affected. See attachment. Thanks
  9. T

    Steam consumption

    Goodday, l want to measure steam consumption(stripping steam) of a deodorizer. l dont have a flowmeter or a nozzle, just a pressure gauge. Please find attached the schematic of my problem.
  10. T

    Non return valve

    Goodday, Does a non return valve have a valve flow coefficient? l want to calculate mass flowrate of steam through a non-return valve. Your assistance will be much appreciated.
  11. T

    motor

    goodday, my plant flow diagram state l require 10HP compressor. Does it mean any 10HP compressor will work or l need further information?
  12. T

    Pump selection

    Goodday, l have the following PFD and it says l want 5hp pump, does this refer to the pump itself or motor? lts P601-A