Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: GTrinh97
  • Content: Threads
  • Order by date
  1. GTrinh97

    Vibration isolation

    I'm currently researching vibration isolation methods for a residential project where a rooftop mechanical unit is supported by wood framing. I’m curious if anyone has dealt with a similar setup and can share their experience. Would it be more effective to isolate just the equipment base, or...
  2. GTrinh97

    Vibration Isolation

    I'm currently researching vibration isolation methods for a residential project where a rooftop mechanical unit is supported by wood framing. I’m curious if anyone has dealt with a similar setup and can share their experience. Would it be more effective to isolate just the equipment base, or...
  3. GTrinh97

    Extended Single Plate Connection

    I am designing a single shear tab (extended shear plate) connection for a W6×15 beam supporting mechanical equipment. However, I am facing challenges due to edge distance limitations and the fact that the AISC manual permits the column to be designed for axial force without eccentricity. Since...
  4. GTrinh97

    Splice Connection

    I am working on designing a bolted beam splice connection for a W-Beam, with the splice located at one-third of the beam's length. However, after reviewing the AISC Steel Construction Manual (15th Edition, Volume 1), I was unable to find an example that specifically addresses this type of...
  5. GTrinh97

    Risa 3D Steel - Concrete Column

    Hi everyone, I have a question about designing a composite column with HSS infilled with concrete. I'm not quite sure how to approach this in RISA-3D. Does anyone have any suggestions or guidance on how to get started? Thanks in...
  6. GTrinh97

    Bar Metal Grating

    I am looking for the dead load of this grating to design the structure below. I haven't been able to find any resources for this specific size of grating. Grating (field note): 1. Width: 5' - 7 1/2" 2. Span: 26' - 3/8" 3. Bearing Bar Depth: 5 1/2" 4. Bearing Bar Thickness: 1/4" 5. Bearing Bar...
  7. GTrinh97

    ASCE 7-16 -c&C Roof

    Should I treat it as flat roof or gable/hip < 7 degree? https://files.engineering.com/getfile.aspx?folder=8eb38e2c-bd85-4dd6-b02f-ab7509b9f38a&file=Screenshot_2024-06-19_115819.png
  8. GTrinh97

    Splice Beam

    I am looking for similar method of securing metal to wood, but the contractor prefers using Simpson Strong-Tie products. The Simpson ties available are typically designed for either compression or tension, but my design needs to handle...
  9. GTrinh97

    Screws and Nails

    Any screw that can go from the steel plate first then go through the wood beam? https://files.engineering.com/getfile.aspx?folder=f564f4de-4827-44d8-ab7c-f3bad36eb37d&file=Screenshot_2024-05-28_131540.png

Part and Inventory Search