Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: meistersd
  • Content: Threads
  • Order by date
  1. meistersd

    Soil Structure Interaction in ETABS

    Hello all! I am trying to model soil structure interaction in ETABS for a G+9 RCC Framed Building with a single basement below ground level and Raft Foundation at the base. I am trying to employ Substructure Method for modeling of soil structure interaction and primarily basing my work on...
  2. meistersd

    Flexural Design Results in ETABS for Columns

    Below I have uploaded a screenshot of Column Flexural Design Details in ETABS based on Indian Code. I have a few questions regarding the design results and I would be grateful if somebody could clarify them to me!! 1. What is the purpose of calculating Initial Moment? How is Initial Moment...
  3. meistersd

    End Releases for Truss Members in ETABS

    I am designing a three-storey steel building in ETABS with roof truss. Should we assign end releases to the truss members? If so, what is the proper way to apply end releases? I see that even when end releases are not applied, and we check for axial/shear/bending moments in those truss members...
  4. meistersd

    Lateral Bracing in ETABS

    When we are designing a steel structure in ETABS, I see that we can assign lateral bracing to the main beams supported by secondary beams. Should we always assign this property to the floor beams? What is the significance of assigning this lateral bracing? How can we be assured that the...
  5. meistersd

    Shear Wall Design Inadequacy in ETABS

    I am designing an 8-storey RCC building in ETABS with lift core and shear walls. While designing for Shear Wall, I get the error message as indicated in the picture attached with this post. Currently, I have defined 250 mm thick wall section. However, the wall is failing in flexure and also some...
  6. meistersd

    Modeling in ETABS

    Hello, When analyzing a building in ETABS, deflection can be seen only for the topmost storey as shown in the picture that I have attached along with this thread. Can anybody tell me what might be the reason for this and what is the solution for...
  7. meistersd

    Error in Modeling in ETABS

    Hello, I modelled an 8-storey building in ETABS with a Basement and Lift Core. After modeling and application of all loads, when I perform analysis I can see only the topmost storey deflecting. There doesn't seem to be any deflections in the storey below. As a result of this, the time period in...
  8. meistersd

    Torsional Irregualrity in Building

    Hello! I analyzed a fairly regular and symmetric building in ETABS and I was checking the results of Modal Analysis as per IS 1893 (Part 1): 2016. Code says that "the fundamental lateral natural periods of the building in the two principal plan directions should be away from each other by at...