This is a curious question Ive been asked. Im quite familiar with a plastic bag blocking a API tank vent and a vacuum being pulled with resulting tank damage => and see it first hand many years ago as a student on an API MEOH Tank.
But, Im fairly sure the answer is NO.. but for API tanks is...
This is general. 3D modelling software question.
I've recently been advised with the current software tool used - it is difficult to represent round handles in the model output visual display so round handles are shown as pan handles. The same for extended handles around insulation...
We are installing new CCTV cameras on a project and I want some feedback experience of electrical teams on providing solar powers (maybe) dual supply or dual batteries to power security cameras ?
technology of power generation and storage seems to have moved on a lot.. so at 60watt type power...
Packed Bed L/D to avoid channeling :
I am after a rough guide / or basic validation to avoid Channeling in packed beds .. for activited carbon treating a product to remove order.
Hopefully this is ok to ask
in the Re-tube process of a fixed tubesheet. Id like to validate my understanding of the process.
Is it as below
1. Grind out welds on all tubes
2. Pull all tubes out.
3. re-detail (tube sheet)
4. insert new tube sheet
5. reweld up tube sheet.
with a very large...
Hopefully this is ok to ask.
I'm going through NPFA 30, to understand a proposal I've been given. (I will ask the vendor as well)..
(and sorry if its obvious).. On CH16, Im struggling to see what determines if I have Class II combustible
Class IIIA combustible , Class IIIB combustible -...
Hopefully this is ok to ask.
Id like to validate that its only a convention in the UK that electrical cables are black and red above a certain voltage etc..
from what i can tell its what is normally done .. not a standard otherwise this is only cable colour you would normally get
Please delete if not ok to ask:
All the literature I can see (and the info ) from valve vendors (Ive found so far).. is that rugosity of GMP valves is always 0.8 or less.
A chemist in our organization has asked can we get lower , say 0.5 . We have some drivers for a lower spec for quality...
Hi,
Sorry if this basic questions and not approprate please delete..(sorry)
I am a project engineer without an EI background. but a moderate experience with this..
I'm looking to get a background basic understanding of capacities and system setup.
Why I am asking:
> Site project to...
For piping design of GMP systems is there an EU / British standard which must be followed.
The current systems on a unit we have is clamp ring. Is there an EU standard or reference which dictates this.
thanks
Im not sure exactly where to post this.
I'm supporting a GMP plant. I after a design guide for general GMP practice..
is it a GMP requirement to have flooring plate ? (on 1st,2nd. 3rd floors..)
or is the requirement just to be clean.. and generally structural steel floors are plated to...
(None electrical engineer question here. so applogies)
is there a standard which defines how you manage an electrical cabinet MCC/ Switch gear in an area with a wet springler system.
this is an exsiting system but also plans to put new cabinets in.
fire protection is required in general area...
Dear Pipers..
Is their a list to what is expected as "common" practice for a SEP -Piping system under PED for a handover package from a contractor.
I'm finding a variety of detail being provided.. and struggling to get a recommendation..
is there any decent info or background references one...
Dear all,
i like to confirm my understanding of the limit for balanced bellows relief valves.. can you get a valve with a set pressure and balanced bellows below 1 barg?
i Dont believe so but i wanted to check
thanks in advance
Apologies if this has been asked before for different levels of voltage is Medium 415 V, 11KV etc.. is there a minimum separation distance from mult-mode fibre optic cable?
or a design code which should be followed to design too. For a mixture of overheads cable racks and ducted cable runs...
Hi,
I'm after some short advice here or a decent rule of thumb calculator to approximate the potential to cool about 1.5 te/hr in 1 inch pipe from around 200 to 60 C in finned pipe.
Its a basic oil fluid.
From a quick google search typical HTC id assume would be 500 w/m2 K, but I need a...
ive recently come accross some specs internally that say
> FO's you need 5 upstream and downsteams. (not the flow meters) the standard FO's for pump min flow recycles on pumps.
I've not seen this before as 20+ years as a process engineer, has apparently its due to pipe errosion has anyone...