  1. cme

    Type ERW or Type S pipe

    Which do you specify for chilled and hot water systems?
  2. cme

    Commissioning of dampers

    Is actual commissioning of fire, F/S and smoke dampers involve whether they close w/o binding or is it just installation checks such as for sleeve clearance, breakaway connections, access doors, etc?
  3. cme

    Duct Shaft Wall

    I have a 6 story healthcare building. Each air handler (2 total) is around 140,000 cfm. What type of construction is permissable for the supply and return shafts? How are the takeoffs for each floor sealed at the shaft? Leakage testing advised?
  4. cme

    Chiller factory testing

    What type testing should I specify regarding centrifugal water cooled chiller factory testing? Full load operation only with tonnage calculation? Verification of chiller operation throughout its entire range without shutdown due to nuisance trips? Measurement of current draw at max operation...
  5. cme

    Dynamic fire damper listing

    I have been specifying Ruskin DIBD-2 fire dampers since I started my career It has been brought to my attention that those dampers are not UL listed in horizontal installations for sizes larger than 24x24...
  6. cme

    Air changes in life science lab

    My calcs indicate 9 air changes per hour for the labs .... 100% OSA ..... 49 deg F space temp The writeup from the school says 10-12 ACH occupied I am providing 15.6 ACH Is this adequate for control of odors? The spaces are for cadaver disection .... no BSC's
  7. cme

    Clothes dryer exhaust

    I have 4 dryers connecting to a common duct/exhaust fan. My 2 schemes of thought of design/control as follows: Scheme 1: Have a "draft hood" type arrangement (indirect connection) where the dryer exhaust would discharge into the exhaust duct such that there would be a gap between the ducts...
  8. cme

    Refrigeration reheat inquiring

    I have a project involving a 70 ton rooftop MAU seving a science lab. 100% OSA. Basis of design is around AAON with a modulating hot gas reheat coil / scheme. I'm looking at McQuay RPS model and their reheat scheme is via a subcooling coil between the condenser and TXV. Would welcome your...
  9. cme

    Waste Oil Burner

    Is there any MFR or a waste oil burner/boiler in the range of 200 BHP? This would give me 2 boilers at 2/3 capacity each. Any experiences with this application?
  10. cme

    Health Science Lab

    I have just been given a 20,000 SF health science lab building for a major university in NY. Are there any special code authorities / regulations / guidelines. Thanks.
  11. cme

    Slim line fan coil needed

    I got a problem with very little ceiling space for a 4-pipe fan coil units to serve a corridior. 7" total ceiling space for ceiling mounted units .... similar to EMI CAF4-08 ....... EMI's are 9+" Will take a wall mounted (up high) near the ceiling ..... something slimline w/ integral...
  12. cme

    McQuay ALS chiller inquiry

    I would like your input/experience with McQuay's "new" screw chiller model (ALS) that has been supposedly redesigned becuase of the amount of failures from its predecessor.
  13. cme

    Morgue design inquiry

    I've got a morgue design added to the scope of work. The hospital is a small coal town in PA and the morgue is used from time-to-time by the county coroner. The current system has 2 fans, 1 exh, 1 supply and a residential window shaker AC unit. Supply fan is shut off. The window shaker is...
  14. cme

    Calling old-timers - stumped on valve

    I was at a site earlier and was looking at the existing heating water plant for retro-fitting pneumatic controls to DDC. There are 2 3-pass firetube boilers, 40 yrs old (defunct mfr), retubed and w/ newly installed burners. Prob 100 hp or so. No water treatment to be found. No backflow...
  15. cme

    HFC-407C

    What's your thoughts/experience with 407C in regards to charging ..... If a leak were to occur, would the machine require a complete new charge or just topping out w/ 134A be sufficient. This pertains to York's YCAS air cooled screw chiller in which I may force them to bid another model w/ 134A...
  16. cme

    CHW system question

    Is an air separator reqd on chilled water systems? If yes, inline or rolaritrol? If yes, then why.
  17. cme

    Smoke control system for atrium

    I've just been handed a task of calculating and designing the smoke control system for an atrium. The project is a 9 story (occupied) hospital in Atlantic City, NJ with a mech/elect penthouse and heliport directly above that. The atrium in question is 3-stories in height with the opening...
  18. cme

    Energy savings from cooling load reduction

    I am trying to calculate the cooling energy savings freehand via psych chart and a formula. I have a formula for heating and am looking for one for cooling. My psych chart tells me I'm reducing the load by 52 tons by going to a return air system. The system will then have 95.5 tons for a...
  19. cme

    High velocity rectangular elbow pressure drop

    I have been assigned to an air handler replacement project serving a lab of a hospital. The system is 100% OSA, dual-duct and has approx 16,500 cfm at 60 deg supply air to the space. The new system will supply 20,000 cfm and possibly 52-54 deg air range. At that cfm, the lab will have about 1.5...
  20. cme

    Fuel oil pipe sizing

    I need to size some fuel oil pipes. Its been over 10 years since I did that. Any websites with charts and procedure/guidelines?