Hello everyone! I have a well pump that can generate -0.5barg on its suction side. I am intending to use this pump to suck water out from a tank. The pump is located 3m above the top water level. I want to get some advice on the sizing of the pipe from the tank to the pump.
1) can I just size...
Hello Guys,
I have a submerged channel with several openings in between. Would like to check if I can calculate the loss through the openings using k-value=2.6 of submerged orifice. So for the example shown below, the loss would be n*k*(v^2)/(2g) = 3*2.6*(v^2)/(2g).
What are your thoughts...
Hi,
I have a 12(W)x18(L)x1m concrete tank installed underground and it will be subjected to pressure of 0.5bar.
To test the tank for leaks, instead of pressurizing the tank using pumps or air blower, my supplier suggests we use a 1 inch hose with 1 end connected to the top of the tank...