Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: jakeh76
  • Content: Threads
  • Order by date
  1. jakeh76

    Connection design LRFD or ASD?

    What is everyone using for seismic connection design? The new provions have an ASD section our people using this or using the ASD? Thanks.
  2. jakeh76

    Explaination of Seismic Force Resisting Systems

    Can anyone tell me where to find an explaination of the types of lateral force resisting systems that are listed in IBC 2000 Table 1617.6.2. I'm really talking about what they mean by "detailed"," ordinary", "special" and "intermediate". Examples of what...
  3. jakeh76

    Connection w/bolts and welds?? Slip Critical?

    In the Schaum's Outline for Steel Design on page 163 in the connection chapter it says if a connection is to be made of both welds and bolts that the bolts must be slip critical? Where I can I find this in the AISC mannual or codes? Are these to be "SC" because of possible load...
  4. jakeh76

    Penetrations through Concrete Beams

    Anyone have any good references for designing penetrations through concrete beams? Thanks.
  5. jakeh76

    Shear Stud Welding in Cold Weather

    What precaution and adjustments should be made during cold weather for the welding of shear studs onto a composite beam? Any good references or sources?? Thanks.
  6. jakeh76

    Auger Cast Piles

    What are the primary differences in "Auger Cast Piles" and Cassions? Is there another name for an "Auger Cast Pile" Any good references for design? Thanks.
  7. jakeh76

    Beefing Up Composite Beams

    I am trying to reinforce an existing composite beam. The beam is a W12X14, 20' long, with a 5" concrete deck. There are 21 uniformly spaced shear studs across its length. Are their any references that cover something like this?
  8. jakeh76

    Estimating Min. Dry unit weight

    I'm trying estimate the min dry unit weight of a cohesionless backfill we will be using. I am in need of this value to estimate (Ko)for a wall with compacted backfill. I have: Max Dry Density D85 D30 Cu D60 D15 D10 Classification Any help would be appreciated. Thanks
  9. jakeh76

    What organization is the "Authority" in wood construction?

    What organization is the "Authority" in wood design and construction? What I mean by this is who is the equivalent in wood design and construction as AISC is to steel design and construction? Thanks
  10. jakeh76

    Wood I-Joist Vibrations

    Anyone have any experience with using wood I-joists. I am considering using them and wood like some input from anyone that has spec'd them. I am looking at span of around 20-25' with 5/8" flooring above. Thanks.
  11. jakeh76

    Lateral Bracing of Steel Beam by Wood Flooring

    Any input on top flange bracing of a W-shape steel beam with 5/8" flooring? I've read this is fine to do..Any comments or references on the subject would be appreciated. Intution tells me that the bracing strenth of the flooring is very minimal. Thanks.
  12. jakeh76

    Composite Beam Studs

    Is there a standard for the minimum cover over a compsite beam stud? Any suggestions would be appreciated. Thanks.
  13. jakeh76

    Active vs Earth Pressure

    Can someone give a me an explanation of the differences and when to use each of the two earth pressures. I've read allot about it it seems kinda vauge about when to use each. If you know of any good references that would be great also. Thanks.
  14. jakeh76

    References for Soilder Pile Wall Design

    Can anyone give me a good reference for the design of soilder pile walls? Thanks.

Part and Inventory Search