Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Frost heave

MramJ

Civil/Environmental
Aug 26, 2023
6
Hello everyone,


I am looking for a way to estimate frost heave of soils without specialized laboratory testing or investigation. I have frost depth, hydrometer results (showing 54% silts), and moisture content.

Is there a straightforward way to obtain a reasonably acceptable estimate with a factor of safety?

Thank you
 
Replies continue below

Recommended for you

Reason why they can’t remove?
If they are installing insulation follow shallow foundation design for frost protection
Is this heated or unheated space?
What is the function?
Would the compressible foam compress under dead load or is there a foundation load path that spans the area?
 
Silts are very bad for frost heave... you have to try to eliminate the frost... extruded polystyrene? High strength if necessary.
 

Part and Inventory Search

Sponsor