Thank you cvg.
Yes it would have been easier just to have a plug. But we have some pollution related problems here, letting in salt water to a sweet water lake.
The Velocity in the larger pipe is app 2m/s. This will force a velocity of approx . 32 m/s in the bypass line.( It would be some thing...
I have a problem. A colloing water ipe line 2.2 m dia. supplies water from the sea to a power station. The water, hot , after cooling the machinery is pumped back into the sea through a similar parallel line.
When the shutdown takes place for the plant, silting takes place inside the incoming...
Thank you, Prex. Can you guide me to the preparation of connection details? like If I know Howmany bols to be used, Which angle to be used for a Beam to Beam Shear Connection?
Thaks prex.
Shenoy
Can Anyone help me getting AISC Steel Shapes Sectional Properties on the Web? I was told there are some sites from which one could download the Properties.
Can Anyone help me getting AISC Steel Shapes Sectional Properties on the Web? I was told there are some sites from which one could download the Properties.
I am in South India. <br>
In our region, many plants and mega Industries are all set to start. But, Due to the So called environmentalists, Industries face a tough time to start. The Pseudo Environmentalists propagate so much of misinformation about the industries- like One MT of Cement...
Thanks a lot Ginger.<br>
<br>
The requirement is when the Const. drgs are not available. The cover meters do cost app US $2000 onwards. unfortunately, this cost is prohibitive for indians. Do u know some Indian Manufacturers/ Indian suppliers of equipment? Or any agency which can supply in...
TJB, yekta,<br>
<br>
I think The placement of 4 Mech. Structures on these Three RCC Columns is important too. isn't it yekta? 50 years Old structure is not a matter at all. Is there a platform? 760 sq. pillar of 2-2.5 m height is not slender. its a short column. Tell us more about Reinforcement...
STAAD /Pro Does Analysis & Design together. STRUDL is another one. SAFI is a good Analysis Program. If you are interested in RC FRAMES, Check out www.roynshenoy.com and then software section. A Good Column Design software is there. COLDES.<br>
Automation of Detailing( Drafting) is not that...
Hi all!<br>
Are there economical methods for checking the Reinforcement pattern, Size of rebar, cover etc.? These Cover meters are a bit expensive. Does anybody have a cheaper NDT Procedure or equipment. <br>
Regs.<br>
Shenoy.
Orama,<br>
Let's not worry about the Name of the subroutine. What is your requirement? Solution of Simultaneous equations? In banded form? see Mtrix Methods by John Meek. There's a listing and it works. If you don't get this book, tell me I shall mail an equivalent subroutine. <br>
Shenoy<br>...
Hi Orama and Mike,<br>
I had been a Strong Fortrner too! I still have my old programs for FEM, Suspension Bridges, Designs. I still use them with VB/Pascal Preprocessors & Post Processors. I still Feel that Fortran has many Stright forward techniques like EQUIVALENCE Statement, which is done in...
Indian Standards Gives a method for the design of slender RCC Columns subjected to biaxial bending. I have a software called COLDES which is capable of designing such columns. email me roynshenoy@vsnl.com or visit www.roynshenoy.com and see the software section.<br>