Hello,
I had a question from my HVAC mechanic in regards to the plumbing on 5 of our air handler units. I am not very experienced with HVAC systems yet and from what I can tell the line in question serves no purpose.
The line in question is the one that bypasses the coil and would allow...
I'm not sure right now what measurement it may need. I've only used the basic meters in the past and I'm having the feeling one of those "won't know you need it until you have it" situations. A couple of biomeds I have spoken with recommended the Fluke 87v so I guess whatever the equivalent...
I need to purchase a digital multimeter for our biomed department and running up against a wall in finding information and reviews on various ones. It seem the Fluke 87-V (or 5) is very popular. Are they any others worth looking at or just use the Fluke? Saw some with a OLED screen but the...
any suggestions on a brand or size of solar panel for such a system? The ones I have listed on my spec template are no longer in production and I'm not sure the companies are in business either. It will be used to charge a battery that powers the transmitter.
Hello,
We are looking to redo our current water-tower water level controls. Our current controls have numerous issues both in the communications and the wiring. Rather then run new communication wires (very old facility and not easy to run wiring) I would like to use a remote telemetry...
Hi guys,
Recently someone mentioned the need of using safety wire on bolts someone had on a application that keep coming loose and shearing.
I said safety wire doesn't keep the bolts from loosening just from completely falling out once they loosen. To this I got several people give me blank...
Free advise huh so what is the purpose of Eng-tips? I only asked for places to find information, if someone wanted to make suggestions that was fine but was not what I primarily asked for.
We have a project to have a local company do an evaluation of our system and provide a report of...
Hello,
I work at a small hospital and am looking for some information on surge and lightning protection. Bit of background, last summer we had one confirmed and possible one other, unconfirmed, lighting strikes to the hospital building. It damaged a number of HVAC control boards and several...
Here are some rough numbers:
CG 28"
Wheelbase 101"
Setup as is
IC X axis: 47.38"
IC Z axis: 135.56"
~AS%: 129
Raised Lower Axle Mount 0.75"
IC X axis: 116.29"
IC Z axis: 491.63"
~AS%: 87
Raised Lower Axle Mount 0.9"
IC X axis: 254.13"
IC Z axis: 1203.75"
~AS%: 78
Raised Lower Axle Mount...
Hi,
What I have is a Jeep with a lifted suspension and stock control arm mounting points. It is a three link with a panhard bar. Suspension works great for most everything except when trying to climb a ledge. Due to the Factory designed short arm and mounting points the front suspension...
They replaced all three. The fuses are on the last pole before the lines drop into the transformers. They also upgraded the fuses I believe on the primary transformer. The transformer is a 100KVA.
There has not been an equipment replaced in probably the last ten years or more. The power...