In the paper manufacturing we provide (2) air systems from the same compressing station. Referred to as essential & non-essential. Paper has very large equipment that requires a controlled shutdown and these critical pieces are fed from the essential side, all else from the other.
Weak outside wall. Point the end at the wall. Assure no cafeteria, meeting room is along axis. Its not Code as I'm aware, just good engineering practice.
If Flammable vapors are present normally ID1, If Flammable vapors are present abnormally (ie) by accident ID2. Vapors are probably heavier than air (confirm) then ventilation in at top out at bottom (sp gr based). Ribboms on vents confirm air movement.
Most sites I've worked (within one company) had test benches we used for non-code/non-UV testing. One site I gained the ability to adjustment within spring range of all UV valves from the State Inspector.
If test sites were not close we required VR test data accompany the valve, for legal...