Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by mylexicon

  1. mylexicon

    NEMA SM-23 criteria for external loads on Turbines/Compressors!

    I am calculating and checking the piping loads at nozzles of a 2 stage compressor which may also operate in parallel. Compressor assembly drawing shows a Low pressure and High pressure side (each with an Inlet & an Outlet nozzle) on either side of the Motor. When checking the combined...
  2. mylexicon

    Fatigue analysis SS (austenitic) piping

    jte- you mean I won't find Fig. 5-110.2.2 in more recent editions of VIII Div 2? I only have the 2007 edition and just scanned through it and could not find these curves! btw, I do have an old copy of Fig. 5-110.1 (from VIII, Div 2) which is the design fatigue curve for CS, low alloy, ...,high...
  3. mylexicon

    Fatigue analysis SS (austenitic) piping

    I was trying to perfom a dynamic (harmonic analysis) on a piping system of SS austenitic type) material. In order to check my dynamic stresses, I was looking for the appropriate source of reference and the applicable S-N (stress range vs. no. of cycles) curve. So, I did some reading and I am a...
  4. mylexicon

    Roof seal for Floating Roof Storage Tanks

    MJCronin Thanks a bunch. great site.
  5. mylexicon

    Roof seal for Floating Roof Storage Tanks

    IFRs How exactly do you mean when saying: 1)"Tube seals test better in the lab..." 2)"Mechanical seals are less efficient in the lab..." Do you mind elaborating a bit on the above statements? What kind of tests do they perform on these 2 types of seals that render these results? If it is too...
  6. mylexicon

    Steam Out analysis

    NozzleTwister & JohnBreen First of all, I wanted to thank you guys for the informative replies you've posted. One question though; Don't they usually detach the piping from equipment (especially rotary types) nozzles and blind it before conducting steam out. This way, we won't have to worry...
  7. mylexicon

    Roof seal for Floating Roof Storage Tanks

    BigInch If you already know this, then ignore this thread. However, if this tank was to be erected in a rainy climate we certainly would have to worry about rain. Floating roofs usually come with roof drainage systems which are gravity drained through hoses hanging off the roof deck and...
  8. mylexicon

    Roof seal for Floating Roof Storage Tanks

    What are the pros and cons of using "Tube seal" vs. "Mechanical seal" or vice versa to seal off the gap between the roof and shell of an Atmospheric Storage Tank? I work on this project which involves erection of 500,000 BBL Atmospheric Storage Tanks for storing Heavy Crude Oil and the...
  9. mylexicon

    Limitations of Spiral Weld Joints in Pipes

    grampi1, By saying "Sour service is a higher risk for SW", Do you mean even if we NACE the pipe, SW pipe is still at risk with sour service? drno
  10. mylexicon

    Limitations of Spiral Weld Joints in Pipes

    BigInch, Thanks for the reply. The only disadvantages that came to my mind regarding Spiral Welded Pipes (hereinafter; SPW) were of practical importance. I think the only down side with using SPW's are difficulties arising during installation such as: 1- Trying to avoid the weld lines...
  11. mylexicon

    Limitations of Spiral Weld Joints in Pipes

    Are there any limitations in using spiral welded pipes for pipelines transporting crude oil(onshore & offshore)? If so according to what code or standard? I am actually worried about the conditions and stresses arising during installation of offshore pipelines. I have checked in ASME B31.4...
  12. mylexicon

    Double-walled Atmospheric Tank for liquid Propane

    I thank you all for caring to reply and your helpful comments. very useful, indeed. drno
  13. mylexicon

    Double-walled Atmospheric Tank for liquid Propane

    Gents, Suppose having Double walled Storage Tanks containing refrigerated Propane (-47°C) at Atmospheric Pressure. Nitrogen blanketing NOT an option. My question is regarding the thermodynamic behaviour of propane inside such tanks? Is this correct to assume that when the tank is partially...
  14. mylexicon

    quote on pipe prices

    Thank you all. MortenA, thanks for the tip. I tried $2/kg for steel. Does that sound reasonable? regards, drno
  15. mylexicon

    quote on pipe prices

    gents, I have been searching over the net for a site that quotes the prevailing unit rates for pipeline prices. I am not even sure if such site exists but I tried and came up empty handed. Any info is highly appreciated. I am preparing a preliminary cost estimate for a 400 km long, 30" dia...