corrosion is more than anything else. you need to make the pole footing a cathode. Also soil horizontal spring contant to control ground line deflection.
@Transmissiontowers, say a standard pair of tension compression diagnals,in plane effective length factor 0.5, rz also 0.5, what is the factor you use for out of plane buckling unbraced length ? 0.7 ?
wood pole is not a manufactured product, the COV is about 20% for MOR under bending.this 10% is a very rough estimate and rather deterministic, it really depends on the pole species and the MOR you use.
If the plate is less than 1/2" thick and the bending angle is no more than 15 deg, cold bending should suffice, but you need a subsequent heat treatment for stress-relief.
So assume you want to check the capacity of an exisiting tower for whatever reason. You go out to the field and you find out these steel angles in dark brown color. You could certainly grind the surface to near white and use a caliper to measure thickness as long as this portion of the tower is...
Can someone share tips on how to model an vintage tower in PLS TOWER, especially member thickness as a result of the loss of material due to corrosion ...